Description
The SCXI-1104C is a high-quality multiplexer featuring a 32 differential channel configuration, designed to handle up to 42 V. It has a part number of 183087H-05, 776572-04C and falls under the SCXI & Legacy category, ensuring compatibility with a range of systems and setups. This model is specifically engineered for applications requiring a dense channel count in a compact form factor.
The device boasts a filter cut-off frequency of 10 kHz, providing ample bandwidth for a variety of signal processing applications. To integrate this device into a multichassis system, the SCXI-1346 adapter is required, ensuring seamless connectivity and expanded system capabilities. Despite its sophisticated design, the analog output of the SCXI-1104C is not overvoltage-protected, though it is short-circuit protected, offering a degree of safety in demanding applications.
For optimal performance, a recommended warm-up time of 20 minutes is advised, allowing the device to stabilize and perform at its best. It operates within a temperature range of 0 to 50 °C, accommodating a variety of environmental conditions. Regular maintenance is minimal, with calibration recommended annually or as needed, ensuring sustained accuracy and performance over time.
Compatibility with NI-DAQ version 6.5.1 or higher software drivers ensures the SCXI-1104C can be easily integrated into existing setups with minimal hassle. Connection options include a 50-pin male ribbon cable (back) and a 96-pin male DIN C (front), offering versatile connectivity solutions for various application requirements.
Despite being announced as obsolete by National Instruments, the SCXI-1104C remains available for purchase and repairs through Apex Waves, providing continued support for users of this reliable and efficient multiplexer. Furthermore, a NIST accredited calibration option is available, ensuring that the device meets stringent accuracy and performance standards.
| Specification | Detail |
|---|---|
| Part Number | 183087H-05, 776572-04C |
| Category | SCXI & Legacy |
| Model | SCXI-1104C |
| Description | 32 ch, 42 V Multiplexer |
| Channels | 32 differential |
| Filter Cut-off Frequency | 10 kHz |
| Required Adapter for Multichassis System | SCXI-1346 |
| Analog Output Protection | Not overvoltage-protected, short-circuit protected |
| Recommended Warm-up Time | 20 minutes |
| Operating Temperature | 0 to 50 °C |
| Calibration Frequency | Annually or as needed |
| Software Driver | NI-DAQ version 6.5.1 or higher |
| Connectors | 50-pin male ribbon cable (back), 96-pin male DIN C (front) |
| Obsolete Status | Announced by National Instruments, available for purchase and repairs by Apex Waves |
| Calibration Option | Available, NIST accredited calibr
Question 1: What is the part number for SCXI-1104C? Question 2: How many differential channels does SCXI-1104C have? Question 3: What is the filter cut-off frequency of SCXI-1104C? Question 4: Is the SCXI-1104C overvoltage-protected? Question 5: Can SCXI-1104C be used with NI-DAQ version 6.5.1? |