Description
“`html
The Part Number for the device is 183087J-04 (776572-04), categorized under SCXI & Legacy. It is a model SCXI-1104, which is described as the National Instruments SCXI-1104 Voltage Input Module. This module is specifically suitable for signal conditioning of high voltage signals, aligning with the Signal Conditioning eXtensions for Instrumentation (SCXI) series.
The channel configuration is designed to be multiplexed into one channel of a controlling DAQ device. It supports voltage signals up to 30 VACrms, ±42 VACpeak, ±60 VDC. Incorporated within the module is a three-pole lowpass filter with a 2 Hz cutoff frequency, ensuring clear signal processing.
However, it does not support ribbon-cabled multichassis SCXI systems, and it requires an SCXI-1346 for multichassis systems. The control interface used is the SCXIbus. For connectivity, devices such as SCXI-1310, TBX-96, BNC-2095, or SCXI-1300 are required.
Software requirements include VirtualBench, ComponentWorks, Measure, LabWindows/CVI, LabVIEW, and the driver requirement is NI-DAQ for Macintosh or NI-DAQ for PC Compatibles. The module is equipped with a 50-pin male ribbon cable back connector, and a 96-pin male DIN C front connector. Its physical dimensions are 4.54 x 10.75 in., and it operates within a temperature range of 0 to 50 °C.
“`
| Specification | Detail |
|---|---|
| Part Number | 183087J-04 (776572-04) |
| Category | SCXI & Legacy |
| Model | SCXI-1104 |
| Description | National Instruments SCXI-1104 Voltage Input Module |
| Suitable For | Signal conditioning of high voltage signals |
| Signal Conditioning Series | Signal Conditioning eXtensions for Instrumentation (SCXI) |
| Channel Configuration | Multiplexed into one channel of a controlling DAQ device |
| Voltage Signals Supported | 30 VACrms, ±42 VACpeak, ±60 VDC |
| Filter | Three-pole lowpass filter with a 2 Hz cutoff frequency |
| Compatibility | Does not support ribbon-cabled multichassis SCXI systems, requires SCXI-1346 for multichassis systems |
| Control Interface | SCXIbus |
| Connectivity Devices Required | SCXI-1310, TBX-96, BNC-2095, or SCXI-1300 |
| Software Requirement | VirtualBench, ComponentWorks, Measure, LabWindows/CVI, LabVIEW |
| Driver Requirement | NI-DAQ for Macintosh or NI-DAQ for PC Compatibles |
| Connectors | 50-pin male ribbon cable back connector, 96-pin male DIN C front connector |
| Physical Dimensions | 4.54 x 10.75 in. |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range |
Question 1: What is the part number for the SCXI-1104? Question 2: What types of signals does the SCXI-1104 support? Question 3: Does the SCXI-1104 include a lowpass filter? Question 4: Can the SCXI-1104 be used in ribbon-cabled multichassis SCXI systems? Question 5: What is the operating temperature range of the SCXI-1104? |