Description
The National Instruments SCXI-1104C Voltage Input Module is a sophisticated piece of equipment designed to offer precision and reliability for various applications. With part numbers 183087J-05, 776572-04C, and 183087H-05, this product falls under the SCXI & Legacy category, indicating its compatibility with legacy systems as well as the state-of-the-art SCXI platform.
The module boasts 32 differential channels, ensuring a wide range of input capability for multiple signal types. The cut-off frequency filter is rated at 10 kHz, providing ample bandwidth for capturing high-frequency signals without compromise. For those looking to integrate this module into a ribbon-cabled multichassis SCXI system, it’s important to note that the SCXI-1346 adapter is necessary for compatibility.
Users can link pin 1,2, 4, or 19 to analog ground, offering flexibility in grounding configurations. Although the module does not feature overvoltage protection, it is equipped with short-circuit protection, enhancing its durability and lifespan. To achieve optimal performance, a recommended warm-up time of 20 minutes is advised before use.
The SCXI-1104C operates efficiently within a temperature range of 0 to 50 °C. However, for maintaining accuracy and performance, an annual calibration is recommended, especially if the module operates outside the specified temperature range. For software interfacing, the module requires NI-DAQ version 6.5.1 or higher, ensuring seamless integration with current data acquisition systems.
The module’s back connector is a 50-pin male ribbon cable, providing a secure and reliable connection to other components within the system. This feature underscores the module’s focus on ease of integration and user-friendly operation.
| Specification | Detail |
|---|---|
| Part Number | 183087J-05, 776572-04C, 183087H-05 |
| Category | SCXI & Legacy |
| Model | SCXI-1104C |
| Description | National Instruments SCXI-1104C Voltage Input Module |
| Channels | 32 differential |
| Cut-off Frequency Filter | 10 kHz |
| Compatibility | Needs SCXI-1346 for ribbon-cabled multichassis SCXI system |
| Analog Ground Pins | Pin 1,2, 4, or 19 can link to analog ground |
| Overvoltage Protection | No |
| Short-circuit Protection | Yes |
| Recommended Warm-up Time | 20 minutes |
| Operating Temperature | 0 to 50 °C |
| Calibration Requirement | Annually or when outside specified temperature range |
| Software Driver | NI-DAQ version 6.5.1 or higher |
| Back Connector | 50-pin male ribbon cable |




