Description
The product with the Part Number 183454G-01 / 777385-01 falls under the category of PC-based Multifunction DAQ. This particular model, named PCI-MIO-16XE-50, offers a guaranteed sampling rate of 20 kS/s. Utilizing successive approximation as its ADC (Analog-to-Digital Converter) type, it ensures precise data acquisition.
It is equipped with 16 single-ended or 8 differential analog input channels, providing flexibility in connecting various sensors. The resolution is impressive, offering 16 bit for input and 12 bit for output, which allows for accurate signal representation. Additionally, this device includes 2 analog output channels, with a maximum update rate matching its sampling rate at 20 kS/s.
For efficient data transfer, it comes with 3 DMA (Direct Memory Access) channels, significantly reducing CPU usage during data transfer. The connector type is a 68-pin male SCSI-II, which is robust and reliable for physical data connections.
Compatibility with driver software is essential, and this device uses NI-DAQmx for seamless integration and easy programming. It supports various Application Development Environments (ADEs) such as LabVIEW, LabWindows, and Measurement Studio, making it versatile for different development needs.
In terms of physical characteristics, the dimensions are 6.9 x 4.2 inches, and it weighs 9.8 oz, making it compact yet substantial enough for secure installation. Despite its many benefits, it is important to note that this model has been announced as obsolete by National Instruments, which may affect long-term availability and support.
| Specification | Detail |
|---|---|
| Part Number | 183454G-01 / 777385-01 |
| Category | PC-based Multifunction DAQ |
| Model | PCI-MIO-16XE-50 |
| Sampling Rate | 20 kS/s (guaranteed) |
| ADC Type | Successive approximation |
| Analog Input Channels | 16 single-ended or 8 differential |
| Resolution | 16 bit (Input), 12 bit (Output) |
| Analog Output Channels | 2 |
| Maximum Update Rate | 20 kS/s |
| DMA Channels | 3 |
| Connector Type | 68-pin male SCSI-II |
| Driver Software | NI-DAQmx |
| Compatible ADEs | LabVIEW, LabWindows, Measurement Studio |
| Physical Dimensions | 6.9 x 4.2 in. |
| Weight | 9.8 oz. |
| Obsolete Status | Announced by National Instruments