Description
The product with part numbers 777306-01 and 183689-01 features a 16 Bit depth, ensuring high-resolution data acquisition. It is equipped with 32 Channels, comprising 16 current outputs and 16 voltage outputs, facilitating versatile applications. Additionally, it includes 8 Digital I/O Lines for enhanced connectivity and control options.
The output range for current is specified as 0 to 20 mA, while the voltage output range is ±10 V, accommodating a wide array of sensors and actuators. Connectivity is ensured through a 68-pin male I/O connector, designed for robust and reliable connections.
Operational efficiency is maintained within an Operating Temperature Range of 0 to 55 °C and a Storage Temperature Range of −20 to 70 °C. The device can reliably function in environments with a Humidity Range of 5 to 90% RH (non-condensing), ensuring durability and longevity in various conditions.
Software compatibility includes NIDAQmx, LabVIEW, LabWindows/CVI, and Measurement Studio, offering flexibility and ease of integration into existing systems. The physical dimensions of 3.9 x 6.9 in. make it compact and easy to accommodate in various setups.
The Maintenance Phase Start Date was initiated on December 30, 2022, indicating ongoing support and service availability. Furthermore, calibration services are available, with a recommendation for calibration either annually or every two years to maintain accuracy and performance.
| Specification | Details |
|---|---|
| Part Numbers | 777306-01, 183689-01 |
| Bit Depth | 16 Bit |
| Channels | 32 Channel (16 current outputs, 16 voltage outputs) |
| Digital I/O Lines | 8 |
| Output Range (Current) | 0 to 20 mA |
| Output Range (Voltage) | ±10 V |
| Connector | 68-pin male I/O connector |
| Operating Temperature Range | 0 to 55 °C |
| Storage Temperature Range | −20 to 70 °C |
| Humidity Range | 5 to 90% RH (non-condensing) |
| Software Compatibility | NIDAQmx, LabVIEW, LabWindows/CVI, Measurement Studio |
| Physical Dimensions | 3.9 x 6.9 in. |
| Maintenance Phase Start Date | December 30, 2022 |
| Calibration | Available, recommended annually or every two years |
Question 1: What is the bit depth of the PCI-6704?
Answer 1: 16 Bit
Question 2: How many channels does the PCI-6704 have?
Answer 2: 32 Channels
Question 3: What is the current output range of the PCI-6704?
Answer 3: 0 to 20 mA
Question 4: What software is compatible with the PCI-6704?
Answer 4: NIDAQmx, LabVIEW, LabWindows/CVI, Measurement Studio
Question 5: What was the Maintenance Phase Start Date for the PCI-6704?
Answer 5: December 30, 2022