184345F-01L

The SCXI-1126 with part number 776572-26, is a frequency to voltage converter with 8 isolated channels, compatible with NI-DAQmx software.

In Stock | Ships Today

img

    Description

    The Part Number 776572-26 refers to a product categorized under SCXI & Legacy, specifically the model SCXI-1126. This product is described as a CCA, SCXI-1126, Frequency to Voltage Converter, designed to convert frequency input signals into proportional voltage outputs.

    It features 8 isolated channels, allowing for multiple inputs to be processed simultaneously without interference. The Input Frequency Ranges are quite versatile, spanning from 250 kHz to 128 kHz across 10 selectable ranges, catering to a broad spectrum of applications. Additionally, it is equipped with Lowpass Filters ranging from 1Hz to 1kHz, which include 4 selectable, 4-pole filters to ensure signal clarity by reducing high-frequency noise.

    The Maximum Input Signal that the SCXI-1126 can handle is up to 250 V, with isolation and overvoltage protection also up to 250 Vrms, ensuring the device’s safety and longevity, whether powered on or off. This makes it particularly suitable for environments with high voltage levels.

    Compatibility with NI-DAQmx software facilitates easy integration with LabVIEW, LabWindows/CVI, and Measurement Studio, offering flexibility in application development and deployment. Connection to the device is made possible through a 50-pin male ribbon cable rear connector and a 32-pin male DIN C front I/O connector, providing reliable and easy setup.

    The device’s dimensions are compact, measuring 1.2 x 6.8 x 8.0 inches, allowing it to fit into a variety of setups without requiring excessive space. Despite its obsolete status announced by National Instruments, it remains available for purchase and repairs through Apex Waves, ensuring continued support for users.

    For those requiring calibration, options are available. This includes NIST accredited calibrations through a third party for precise measurement needs, as

    Specification Detail
    Part Number 776572-26
    Category SCXI & Legacy
    Model SCXI-1126
    Description CCA, SCXI-1126, Frequency to Voltage Converter
    Input Channels 8 isolated channels
    Input Frequency Ranges 250 kHz – 128 kHz (10 selectable ranges)
    Lowpass Filters 1Hz – 1kHz (4 selectable, 4-pole filters)
    Maximum Input Signal 250 V
    Isolation Up to 250 Vrms
    Overvoltage Protection Up to 250 Vrms (powered on or off)
    Software NI-DAQmx compatible with LabVIEW, LabWindows/CVI, Measurement Studio
    Connectors 50-pin male ribbon cable rear connector, 32-pin male DIN C front I/O connector
    Dimensions 1.2 x 6.8 x 8.0 in.
    Obsolete Status Announced by National Instruments, available for purchase and repairs by Apex Waves
    Calibration Available, with NIST accredited calibrations through a 3rd party or basic in-house calibration

    Question 1: What is the input frequency range of SCXI-1126?
    Answer 1: 250 kHz to 128 kHz across 10 selectable ranges.

    Question 2: How many isolated channels does SCXI-1126 have?
    Answer 2: 8 isolated channels.

    Question 3: What is the maximum input signal of SCXI-1126?
    Answer 3: Up to 250 V with isolation and protection.

    Question 4: Is SCXI-1126 compatible with NI-DAQmx software?
    Answer 4: Yes, it’s compatible with NI-DAQmx software.

    Question 5: Can SCXI-1126 still be purchased after being declared obsolete?