Description
The PXI-6040E is a multifunction DAQ board designed for use in PXI systems. This board, identified by part numbers 777484-01 and 184361A-01, offers a wide range of features suitable for various data acquisition tasks. The PXI-6040E is specifically categorized under PXI Multifunction DAQ devices, emphasizing its versatility in handling different data inputs and outputs within a compact and efficient form factor.
One of the key specifications of this DAQ board is its 12-Bit resolution, which ensures precise measurement capabilities for various applications. It supports up to 16 single-ended or 8 differential analog input channels, providing flexibility in configuring the system according to specific requirements. With a maximum sampling rate of 500 kS/s, the PXI-6040E is capable of capturing high-speed signals without compromising data integrity.
In addition to its input capabilities, the board boasts 2 analog outputs, allowing for direct control signals or data output to other devices. It is designed to integrate seamlessly with software such as NI-DAQmx and LabVIEW, which simplifies the development process and enhances the overall user experience with intuitive programming environments.
The PXI-6040E offers exceptional measurement sensitivity, with a minimum detectable change of 0.008 mV, ensuring accurate readings even in applications requiring fine detail. It employs a 68-pin male 0.050 D-type I/O connector, facilitating robust and reliable connections to external sensors and actuators. The input impedance is rated at 10 kΩ, which is ideal for a wide range of sensors.
This DAQ board supports various input modes, including Non-referenced single-ended, Differential single-ended, and Referenced single-ended (RSE), providing further adaptability to different measurement scenarios. It features the NI PGIA (Programmable Gain Instrumentation Amplifier) for enhanced signal amplification and quality.
Before use, a 15-minute warm-up time is recommended for the best performance. To maintain
| Parameter | Specification |
|---|---|
| Part Number | 777484-01, 184361A-01 |
| Category | PXI Multifunction DAQ |
| Model | PXI-6040E |
| Description | PXI-6040E BOARD ONLY |
| Resolution | 12-Bit |
| Analog Input Channels | 16 single-ended or 8 differential |
| Maximum Sampling Rate | 500 kS/s |
| Analog Outputs | 2 |
| Software | NI-DAQmx, LabVIEW Integration |
| Measurement Sensitivity | 0.008 mV |
| I/O Connector | 68-pin male 0.050 D-type |
| Input Impedance | 10 kΩ |
| Input Modes | Non-referenced single-ended, Differential single-ended, Referenced single-ended (RSE) |
| Amplifier | NI PGIA (Programmable Gain Instrumentation Amplifier) |
| Warm-up Time | 15 minutes |
| Calibration Interval | At least once a year |
| Physical Dimensions | 6.3 x 3.9 in. |
| Operating Temperature Range | 0° to 55° C |
| Obsolete Status | Announced by National Instruments |
Question 1: What is the sampling rate of the PXI-6040E?
Answer 1: 500 kS/s
Question 2: How many single-ended channels does the PXI-6040E support?
Answer 2: 16 single-ended channels
Question 3: What is the resolution of the PXI-6040E?
Answer 3: 12-Bit
Question 4: Can the PXI-6040E integrate with NI-DAQmx and LabVIEW?
Answer 4: Yes, it integrates with NI-DAQmx and LabVIEW.
Question 5: What is the minimum detectable change of the PXI-6040E?
Answer 5: 0.008 mV