Description
“`html
The product detailed herein is a PXI Multifunction DAQ unit, model PXI-6040E, which is designed to meet various data acquisition requirements. The DAQ unit comes with part numbers 777484-01 and 184361A-01, ensuring users have the necessary references for support and purchase.
This DAQ system boasts a 12-Bit resolution, providing precise data measurements and analysis. It is equipped with 16 single-ended or 8 differential analog input channels, making it versatile for various types of sensors and inputs. The unit can achieve a maximum sampling rate of 500 kS/s, which allows for high-speed data capture and processing.
Additionally, the PXI-6040E features 2 analog outputs, enabling users to output processed signals or to use the module in control applications. It is compatible with a range of software including NI-DAQ, LabVIEW, LabWindows/CVI, and Measurement Studio, offering flexibility in programming and data analysis.
The device’s measurement sensitivity is remarkably high at 0.008 mV, ensuring that even the most subtle signals can be detected and analyzed. It employs a 68-pin male 0.050 D-type I/O connector, facilitating easy and reliable connections to external devices.
With an input impedance for trigger inputs of 10 kΩ, it ensures compatibility with a wide range of signal sources. The PXI-6040E supports multiple input modes including Non-referenced single-ended, Differential single-ended, and Referenced single-ended (RSE), providing flexibility in signal acquisition.
An integrated NI PGIA amplifier enhances signal quality and measurement accuracy. Users are recommended to allow a warm-up time of 15 minutes for optimum performance. To maintain accuracy and reliability, a calibration is recommended at least once a year.
“`
| Specification | Detail |
|---|---|
| Part Number | 777484-01, 184361A-01 |
| Category | PXI Multifunction DAQ |
| Model | PXI-6040E |
| Resolution | 12-Bit |
| Analog Input Channels | 16 single-ended or 8 differential |
| Maximum Sampling Rate | 500 kS/s |
| Analog Outputs | 2 |
| Software Compatibility | NI-DAQ, LabVIEW, LabWindows/CVI, Measurement Studio |
| Measurement Sensitivity | 0.008 mV |
| I/O Connector Type | 68-pin male 0.050 D-type |
| Trigger Input Impedance | 10 kΩ |
| Input Modes | Non-referenced single-ended, Differential single-ended, Referenced single-ended (RSE) |
| Integrated Amplifier | NI PGIA |
| Recommended Warm-Up Time | 15 minutes |
| Calibration Frequency | At least once a year |
| Physical
Question 1: What resolution does the PXI-6040E DAQ unit have? Question 2: How many analog input channels does the PXI-6040E have? Question 3: What is the maximum sampling rate of the PXI-6040E? Question 4: What software is compatible with the PXI-6040E? Question 5: How often is calibration recommended for the PXI-6040E? |