Description
The part number 777318-401 refers to the cFP-DO-401 model, a specialized digital output module designed for Compact FieldPoint systems. This device, developed by National Instruments, is specifically engineered to enhance the capabilities of Compact FieldPoint setups through its advanced features.
It boasts 16 digital output channels, allowing for extensive connectivity and control options for various applications. The output type of this module is voltage-based, with an output voltage range spanning from 5 V to 30 V. This range ensures compatibility with a wide array of external devices and systems. Additionally, its output impedance ranges from 0.3 to 2 Ω, and it can deliver an output current between 0.67 A to 1.5 A, making it suitable for driving a variety of loads.
The module’s all channel update rate is 20 kHz, enabling rapid response to control signals and system changes. It has a power requirement of 730 mW, indicating its efficiency and low power consumption. In terms of safety and durability, it features a transient voltage tolerance of 2300 Vrms and a continuous voltage protection of 250 Vrms, ensuring the module’s longevity and reliability in challenging environments.
This module is compatible with both 12 VDC and 24 VDC devices, offering versatility in application. For user convenience and system monitoring, it is equipped with 18 green indicators (including POWER, READY, and one for each of the output channels), providing at-a-glance operational status. Lastly, its lightweight design at only 4.1 oz allows for easy installation and integration into existing systems.
| Specification | Detail |
|---|---|
| Part Number | 777318-401 |
| Model | cFP-DO-401 |
| Category | Compact FieldPoint |
| Description | National Instruments cFP-DO-401 Digital Output Module for Compact FieldPoint |
| Output Channels | 16 digital output channels |
| Output Type | Voltage |
| Output Voltage Range | 5 V to 30 V |
| Output Impedance | 0.3 to 2 Ω |
| Output Current | 0.67 A to 1.5 A |
| All Channel Update Rate | 20 kHz |
| Power Requirement | 730 mW |
| Transient Voltage Tolerance | 2300 Vrms |
| Continuous Voltage Protection | 250 Vrms |
| Compatibility | 12 VDC and 24 VDC devices |
| Indicators | 18 green indicators (POWER, READY, and 16 for output channels) |
| Weight | 4.1 oz
Question 1: What’s the part number for the cFP-DO-401? Answer 1: The part number is 777318-401. Question 2: How many digital output channels does it have? Question 3: What’s the output voltage range of the cFP-DO-401? Question 4: Is the cFP-DO-401 compatible with 24 VDC devices? Question 5: What is the all channel update rate? |