Description
The technical specifications of the device include various part numbers such as 778534-01, 778554-01, and 184529D-03. Each of these parts has different capabilities, especially in terms of Analog Input FIFO Buffer Size, where the 778534-01 model has a 16 MS buffer size, and the 778554-01 model doubles that capacity to 32 MS.
With 4 Analog Input Channels, this device offers flexibility in receiving signals. The resolution of these inputs is 12 bit, which ensures a good level of detail in the captured data. For capturing fast-changing signals, the device supports a Maximum Sampling Rate of 10 MS/s, while the minimum rate stands at 20 kS/s, offering a wide range of data capture speeds.
In terms of output, there are 2 Analog Output Channels available, with a Maximum Update Rate of 4 MS/s. Additionally, the device is equipped with 8 TTL/CMOS Digital I/O Channels and 2 Counters with a 24-bit resolution which are essential for complex measurements and control tasks.
The Absolute Accuracy for Analog Input is specified at 184 mV, and the device is BUS powered, eliminating the need for an external power source. It is recommended that the device is warmed up for 15 minutes before use to ensure accuracy, with a Calibration Period advised Annually to maintain precision.
Software compatibility includes LabVIEW, LabWindows/CVI, and Measurement Studio, offering a range of options for data analysis and system integration. The Physical Dimensions of the device are noted as 12.3 x 4, making it a compact and manageable size for various applications.
| Specification | Detail |
|---|---|
| Part Numbers | 778534-01, 778554-01, 184529D-03 |
| Analog Input FIFO Buffer Size | 16 MS (778534-01), 32 MS (778554-01) |
| Analog Input Channels | 4 |
| Resolution | 12 bit |
| Maximum Sampling Rate | 10 MS/s |
| Minimum Rate | 20 kS/s |
| Analog Output Channels | 2 |
| Maximum Update Rate | 4 MS/s |
| Digital I/O Channels | 8 TTL/CMOS |
| Counters | 2 (24 bit resolution) |
| Absolute Accuracy (Analog Input) | 184 mV |
| Power Interface | BUS powered |
| Recommended Warm-up Time | 15 minutes |
| Calibration Period | Annually |
| Software Compatibility | LabVIEW, LabWindows/CVI, Measurement Studio |
| Physical Dimensions | 12.3 x 4
Question 1: What is the max sampling rate of PCI-6115? Question 2: How many analog input channels does PCI-6115 have? Question 3: What is the FIFO buffer size of part 778534-01? Question 4: What software is compatible with PCI-6115? Question 5: What is the calibration period for the PCI-6115? |