The PXI-2565 is a 16-channel SPST relay module with a max switching voltage of 250V AC, 5A carry current, and operates within 5ms.

In Stock | Ships Today

img

    Description

    The Part Number 185664C-01L refers to a high-quality PXI Switch categorized under the model PXI-2565. This device is specifically designed as a Relay Module that facilitates efficient signal routing within automated test systems. It features 16-Channel SPST relay channels, making it versatile for various applications.

    Regarding its operational capabilities, the PXI-2565 can handle a Maximum Switching Voltage of up to 125 V DC and 250 V AC, offering flexibility in dealing with different signal types. When it comes to current, it can manage a Maximum Switching Current of 5 A at 30 V DC and supports a Maximum Carry Current of 5 A DC and 7 A AC per channel. This ensures that the module can handle substantial power loads, with a Maximum Switching Power per channel of 150 W and 1750 VA.

    The device ensures operational precision even at minimal loads, with a Minimum Switch Load requirement of 10 mA, 5 V DC. Its relay operation times are impressively quick, operating within 5 ms (typical) to 10 ms (maximum) and releasing within 4 ms (typical) to 5 ms (maximum). The PXI-2565 is built to last, with a Mechanical Relay Life of 5 × 107 cycles and an Electrical Relay Life of 1 × 105 cycles.

    It also boasts a high level of Isolation, with 1400 Vrms between the backplane to input signals, ensuring safety and integrity in measurements. The module is triggered by PXI trigger lines <0…7> with a minimum pulse width of <

    Specification Detail
    Part Number 185664C-01L
    Category PXI Switches
    Model PXI-2565
    Type Relay Module
    Channels 16-Channel SPST
    Maximum Switching Voltage (DC) 125 V
    Maximum Switching Voltage (AC) 250 V
    Maximum Switching Current (DC) 5 A at 30 V
    Maximum Carry Current (per channel) 5 A DC, 7 A AC
    Maximum Switching Power (per channel) 150 W, 1750 VA
    Minimum Switch Load 10 mA, 5 V DC
    Relay Operation Time Operate within 5 ms (typical), 10 ms (maximum); Release within 4 ms (typical), 5 ms (maximum)
    Mechanical Relay Life 5 × 107 cycles
    Electrical Relay Life 1 × 105 cycles
    Isolation 1400 Vrms (backplane to input signals)
    Triggering PXI trigger lines <0…7> at 70 ns minimum pulse width
    Maintenance Phase Start June 30, 2023

    Question 1: What is the max switching voltage of PXI-2565?
    Answer 1: 250V AC and 125V DC

    Question 2: How many relay channels does PXI-2565 have?
    Answer 2: 16-Channel SPST

    Question 3: What is the max carry current for PXI-2565?
    Answer 3: 5A DC, 7A AC per channel

    Question 4: What is the typical relay operation time for PXI-2565?
    Answer 4: 5 ms

    Question 5: What is the electrical relay life of PXI-2565?
    Answer 5: 1 × 10^5 cycles