Description
The product with part number 777518-520 falls under the category of FieldPoint. It is a FP-PWM-520 model, designed to cater to specific needs in industrial and technical fields. This device features 8 Pulse-Width Modulation sourcing output channels, making it versatile for a variety of applications.
The output period configuration of this model can be adjusted from 1 millisecond to 65535 milliseconds, in 1-millisecond increments, allowing for precise control over the PWM signals. It supports a power supply output of either 5 VDC or 10-30 VDC, which must be provided by the user, offering flexibility in integration with various power sources.
For mounting, it utilizes the FP-TB-x (FieldPoint terminal base), ensuring a secure and reliable installation. This model is designed with optical isolation from the FieldPoint bank, providing enhanced protection and reliability. Additionally, it features short-circuit protection, ensuring safety and durability in challenging environments.
The device can be easily reset through the FieldPoint software, making maintenance and troubleshooting straightforward. Its duty cycle range extends from 0% to 100%, offering complete control over the output signals. The maximum output current per channel is 1 A, suitable for driving various loads.
Lastly, the terminals include 8 PWM output, 16 COM, and 8 Vsup, providing ample connectivity for complex setups. This makes the FP-PWM-520 a comprehensive solution for managing pulse-width modulation outputs in a wide range of applications.
| Specification | Details |
|---|---|
| Part Number | 777518-520 |
| Category | FieldPoint |
| Model | FP-PWM-520 |
| Channels | 8 Pulse-Width Modulation sourcing output channels |
| Output Period Configuration | 1 millisecond to 65535 milliseconds (in 1-millisecond increments) |
| Power Supply Output | 5 VDC or 10-30 VDC (user-provided) |
| Mounting | FP-TB-x (FieldPoint terminal base) |
| Isolation | Optical isolation from the FieldPoint bank |
| Short-Circuit Protection | Yes |
| Reset Method | Through FieldPoint software |
| Duty Cycle Range | 0% to 100% |
| Maximum Output Current per Channel | 1 A |
| Terminals | 8 PWM output, 16 COM, 8 Vsup |
Question 1: What is the part number of the FP-PWM-520?
Answer 1: 777518-520
Question 2: How many PWM output channels does the FP-PWM-520 have?
Answer 2: 8 sourcing output channels
Question 3: What is the output period range of the FP-PWM-520?
Answer 3: 1ms to 65535ms
Question 4: Does the FP-PWM-520 offer optical isolation?
Answer 4: Yes, it has optical isolation
Question 5: What is the maximum output current per channel on the FP-PWM-520?
Answer 5: 1 A