Description
The FieldPoint module with part number 185715C-01 (777518-520) is identified as model FP-PWM-520. This module is a Pulse-Width Modulation (PWM) Output Module designed to offer precise control over the output signals. It features 8 pulse-width modulation sourcing output channels, allowing for a wide range of applications.
The module’s output period can be configured from 1 millisecond to 65535 milliseconds, in 1-millisecond increments, providing flexibility in controlling the duration of the output signal. The output voltage can be either 5 VDC or a user-provided power supply ranging from 10-30 VDC, depending on the requirements of the application.
For installation, the module is mountable on FP-TB-x (FieldPoint terminal base) and supports hot-swapping, which allows for easy replacement and upgrading without the need to power down the entire system. It also features optical isolation from the FieldPoint bank, protecting the system from electronic interference and ensuring reliable operation.
The module includes short-circuit protection with special gear, enhancing the safety and durability of the system. The reset method is conveniently managed through FieldPoint software, allowing for quick and easy troubleshooting. Despite its robust output capabilities, the module ensures a minimum amount of leakage current in the OFF state, preserving energy and reducing unintended signals.
The duty cycle range of the module spans from 0% to 100%, offering comprehensive control over the output signals’ power. Each of the eight channels can handle a maximum output current of 1 A, suitable for a variety of applications. Lastly, the module is equipped with 8 PWM output terminals and 16 COM terminals, providing ample connectivity options for complex configurations.
| Specification | Detail |
|---|---|
| Part Number | 185715C-01 (777518-520) |
| Category | FieldPoint |
| Model | FP-PWM-520 |
| Module Type | Pulse-Width Modulation (PWM) Output Module |
| Channels | 8 pulse-width modulation sourcing output channels |
| Output Period Configuration | 1 millisecond to 65535 milliseconds (in 1-millisecond increments) |
| Output Voltage | 5 VDC or 10-30 VDC (user-provided power supply) |
| Installation | Mountable on FP-TB-x (FieldPoint terminal base), Hot-swappable |
| Isolation | Optical isolation from FieldPoint bank |
| Short-Circuit Protection | Yes, with special gear |
| Reset Method | Through FieldPoint software |
| Leakage Current (OFF state) | Minimum amount |
| Duty Cycle Range | 0% to 100% |
| Maximum Output Current | 1 A per channel |
| Terminals | 8 PWM output, 16 COM
Question 1: What is the part number of the FP-PWM-520? Question 2: How many output channels does the FP-PWM-520 have? Question 3: What is the output period range of the FP-PWM-520? Question 4: Can the FP-PWM-520 be hot-swapped? Question 5: What is the duty cycle range of the FP-PWM-520? |