Description
The National Instruments PXI-6608 PXI Counter/Timer Module, with part number 777937-01, is a sophisticated component designed for accurate timing and counting applications. This module falls under the category of PXI Timing I/O, indicating its high compatibility and performance in PXI systems.
The PXI-6608 is equipped with 8 up/down counters/timers, each offering a resolution of 32 bits. This high resolution ensures precise time measurements and counter operations, making it suitable for a wide range of high-precision tasks. It requires a power input ranging from 1 A to 2.5 A, depending on the operational demand, which showcases its efficiency in power consumption.
Featuring a Schmitt Triggers Hysteresis of 300 mV, the module provides reliable signal conditioning, enhancing its performance in noisy environments. The input impedance ranges from 25 kΩ to 500 kΩ, and the output impedance is maintained at 75 Ω. These specifications ensure that the module can interface with a wide variety of sensors and devices without signal degradation.
The PXI-6608 is capable of measuring and sourcing frequencies up to 80 MHz, making it highly suitable for high-speed applications. It requires a warm-up time of 5 minutes to reach operational stability, ensuring accurate performance thereafter. The module operates within a temperature range of 0 °C to 55 °C and can be stored in temperatures ranging from –20 °C to 70 °C. This wide temperature range indicates robustness and reliability in various environmental conditions.
Furthermore, the operating humidity range for the PXI-6608 is from 0% to 90% (non-condensing), which highlights its capability to perform in a wide range of humidity conditions without compromising the accuracy or reliability of its operations.
| Specification | Detail |
|---|---|
| Part Number | 777937-01 |
| Model | PXI-6608 |
| Category | PXI Timing I/O |
| Description | National Instruments PXI-6608 PXI Counter/Timer Module |
| Counter/Timer Modules | 8 up/down counters/timers |
| Resolution | 32 bits |
| Power Required | 1 A to 2.5 A |
| Schmitt Triggers Hysteresis | 300 mV |
| Input Impedance | 25 kΩ to 500 kΩ |
| Output Impedance | 75 Ω |
| Measure and Source Frequencies | 80 MHz |
| Warm-up Time | 5 minutes |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | –20 °C to 70 °C |
| Operating Humidity Range | 0% to 90% (non-condensing) |
| Storage Humidity
Question 1: What is the part number for the National Instruments PXI-6608? Question 2: How many counters does the PXI-6608 have? Question 3: What resolution do the PXI-6608 counters have? Question 4: What is the operating temperature range of the PXI-6608? Question 5: What frequencies can the PXI-6608 measure up to? |