The PXI-4070 is a high-performance digital multimeter that comes with a part number of 778274-01. This multimeter is notable for its 6.5 Digit FlexDMM feature, which offers precise measurements for a variety of applications. It boasts an impressive sampling rate of up to 1.8 MS/s, making it capable of handling fast signals efficiently.
In addition to its high sampling rate, the PXI-4070 features a 1.8 MS/s Flexible-Resolution Isolated Digitizer, allowing for versatile data acquisition capabilities. The resolution of the digitizer can be varied from 10 to 23 bits, providing flexibility in balancing resolution and speed according to the needs of the application.
When it comes to DC system features, the PXI-4070 offers a range/function change rate of 100/s, an auto range time of 50 ms, a trigger latency of 2 μs, and a maximum trigger rate of 6kHz. These features ensure that the device can quickly adapt to changes in the signal, making it ideal for a wide range of testing and measurement tasks.
The AC system features of the PXI-4070 include a range/function change rate of 10/s, an auto range time of 250 ms, a trigger latency measured in microseconds, and a maximum trigger rate of 1 kHz. These specifications demonstrate the device’s capability to effectively measure AC signals.
One of the key advantages of the PXI-4070 is its self-calibration feature, which enhances precision over a temperature range of 0 to 55 degrees Celsius. Additionally, it is recommended that an external calibration be performed every two years to maintain its accuracy.
The maintenance status of the PXI-4070 is currently available for purchase and repairs by Apex Waves. For calibration, there are options for NIST accredited calibrations through a third party, as well as basic in-house calibration services.
Regarding programming compatibility, the PXI-407
| Specification | Description |
|---|---|
| Model | PXI-4070 |
| Part Number | 778274-01 |
| Digit Resolution | 6.5 Digit FlexDMM |
| Sampling Rate | Up to 1.8 MS/s |
| Digitizer Capability | 1.8 MS/s Flexible-Resolution Isolated Digitizer |
| Resolution Variability | 10 to 23 bits |
| DC System Features | Range/function change: 100/s, Auto range time: 50 ms, Trigger latency: 2 μs, Max trigger rate: 6kHz |
| AC System Features | Range/function change: 10/s, Auto range time: 250 ms, Trigger latency: μs, Max trigger rate: 1 kHz |
| Self-Calibration | Yes, enhances precision over 0 to 55 degrees Celsius |
| External Calibration | Recommended every two years |
| Maintenance Status | Available for purchase and repairs by Apex Waves |
| Calibration Options | NIST accredited calibrations through a 3rd party; Basic in-house calibration available |
| Programming Compatibility | C/C++, .NET, Visual Basic, LabVIEW, LabWindows/CVI |
Question 1: What is the sampling rate of the PXI-4070?
Answer 1: 1.8 MS/s
Question 2: Can the PXI-4070’s digitizer resolution be adjusted?
Answer 2: Yes, from 10 to 23 bits.
Question 3: How often is external calibration recommended for the PXI-4070?
Answer 3: Every two years.
Question 4: What is the part number of the PXI-4070?
Answer 4: 778274-01
Question 5: Does the PXI-4070 offer NIST accredited calibrations?
Answer 5: Yes, through a third party.