Description
The Part Number 185835A-01 refers to a specific model of PXI Switches, named the PXI-2565. This device is categorized as a General-Purpose Relay Switch and is designed with a 16-Channel SPST configuration. It is capable of handling a maximum switching voltage of 125 V DC and 250 V AC (channel-to-channel), with a maximum switching current of 5 A at 30 V DC. Furthermore, each channel can carry a maximum current of 5 A DC and 7 A AC, and the maximum switching power per channel is 150 W or 1750 VA.
The device ensures functionality even with a minimum switch load of 10 mA, 5 V DC and offers isolation up to 1400 Vrms (backplane to input signals). The contact material is made of gold-flash over silver alloy, ensuring durability and reliability. It presents a quick operate time of 5 ms (typical) to 10 ms (max) and an even faster release time of 4 ms (typical) to 5 ms (max). The mechanical relay life is impressive, with up to 5 × 107 cycles, and the electrical relay life is up to 1 × 105 cycles.
For triggering purposes, it uses PXI trigger lines <0…7> with a minimum pulse width of 70 ns. Lastly, it is important to note that the maintenance phase start date for this model is scheduled for June 30, 2023.
| Specification | Detail |
|---|---|
| Part Number | 185835A-01 |
| Category | PXI Switches |
| Model | PXI-2565 |
| Type | General-Purpose Relay Switch |
| Configuration | 16-Channel SPST |
| Maximum Switching Voltage | 125 V DC, 250 V AC (channel-to-channel) |
| Maximum Switching Current | 5 A at 30 V DC |
| Maximum Carry Current | 5 A DC, 7A AC (per channel) |
| Maximum Switching Power | 150 W, 1750 VA (per channel) |
| Minimum Switch Load | 10 mA, 5 V DC |
| Isolation | 1400 Vrms (backplane to input signals) |
| Contact Material | Gold-flash over silver alloy |
| Operate Time | 5 ms (typical), 10 ms (max) |
| Release Time | 4 ms (typical), 5 ms (max) |
| Mechanical Relay Life | 5 × 107 cycles |
| Electrical Relay Life | 1 × 105 cycles |
| Triggering | PXI trigger lines <0…7> at 70 ns minimum pulse width |
| Maintenance Phase Start Date | June 30, 2023 |
Question 1: What is the max switching voltage of PXI-2565?
Answer 1: 125 V DC and 250 V AC
Question 2: How many channels does the PXI-2565 have?
Answer 2: 16-Channel SPST
Question 3: What is the max switching current for PXI-2565?
Answer 3: 5 A at 30 V DC
Question 4: What is the contact material of PXI-2565?
Answer 4: Gold-flash over silver alloy
Question 5: What is the maintenance phase start date for PXI-2565?
Answer 5: June 30, 2023