Description
“`html
The FP-AI-111 is a FieldPoint 16-Bit Current Input Module characterized by part number 185837C-01. It is specifically designed to accommodate 16 analog current input channels (single-ended), making it versatile for a wide range of applications. This module stands out for its high-resolution 16-bit analog-to-digital conversion, ensuring precise data acquisition.
With an update rate ranging from 3 Hz to 0.83 Hz for all 16 channels, the FP-AI-111 guarantees timely data updates, essential for monitoring and control applications. It offers three selectable input ranges, providing flexibility to accommodate various signal levels. Moreover, the module ensures the safety of its circuits with overcurrent protection of ±30 mA for current input channels.
The FP-AI-111 utilizes a delta-sigma ADC type, renowned for its high fidelity and noise rejection capabilities. This module can maintain a resolution of up to 16 bits at 50/60 Hz, and 12 bits at 500 Hz, accommodating a broad spectrum of frequency requirements. It operates efficiently with a power requirement of 350 mW and boasts an input impedance of 100 Ω, minimizing power consumption while maintaining high performance.
Input noise is remarkably low at 0.3 µA, ensuring that signal integrity is preserved. The FP-AI-111 also features two LEDs for readiness and power status, providing immediate visual feedback on the module’s operational state. Its physical dimensions are 4.3 x 4.3 x 3.6 inches, and it weighs 4.8 oz, making it compact and lightweight for easy integration into various systems.
Operating within a temperature range of –40 °C to 70 °C and a storage temperature range of –55 °C to 85 °C, the FP-AI-111 is built to withstand harsh environments. It can operate reliably in a humidity range
Answer 1: 185837C-01
Question 2: How many analog input channels does the FP-AI-111 have?
Answer 2: 16
Question 3: What ADC type does the FP-AI-111 use?
Answer 3: Delta-sigma ADC
Question 4: What is the max overcurrent protection for FP-AI-111 inputs?
Answer 4: ±30 mA
Question 5: What is the operating temperature range of the FP-AI-111?
Answer 5: –40 °C to 70 °C