Description
The Part Number for the device is 185838F-01, with an Alternative Part Number being 777798-01. This device falls under the Category of PXI Multifunction DAQ, specifically the Model PXI-6025E. It features Analog Input Channels that can be configured as either 16 single-ended or 8 differential channels.
The Maximum Sample Rate that can be achieved is 200 kS/s, with the device also providing 2 Analog Output Channels. When it comes to Digital I/O Channels, it boasts 32, alongside Two 24-bit Counters and 1 DMA Channel for efficient data transfer. The Connector Type used for interfacing is a 100-pin connector.
For voltage inputs, the device has an Input Voltage Range of ±11 V (DC input coupling). It supports various Input Modes, including Differential (DIFF), Referenced Single-Ended (RSE), and Non-Referenced Single-Ended (NRSE). Compatibility with software is extensive, including LabVIEW, LabWindows/CVI, Measurement Studio, Visual C++, Microsoft Visual Basic, ComponentWorks, and VirtualBench.
The precision of the Input Range is noted to be 24.41 µV at -50 to +50 mV, with a gain of 100.0, ensuring accurate measurements and data acquisition for various applications.
| Specification | Detail |
|---|---|
| Part Number | 185838F-01 |
| Alternative Part Number | 777798-01 |
| Category | PXI Multifunction DAQ |
| Model | PXI-6025E |
| Analog Input Channels | 16 single-ended or 8 differential |
| Maximum Sample Rate | 200 kS/s |
| Analog Output Channels | 2 |
| Digital I/O Channels | 32 |
| Counters | Two 24-bit |
| DMA Channels | 1 |
| Connector Type | 100-pin |
| Input Voltage Range | ±11 V (DC input coupling) |
| Input Modes | Differential (DIFF), Referenced Single-Ended (RSE), Non-Referenced Single-Ended (NRSE) |
| Software Compatibility | LabVIEW, LabWindows/CVI, Measurement Studio, Visual C++, Microsoft Visual Basic, ComponentWorks, VirtualBench |
| Input Range Precision | 24.41 µV at -50 to +50 mV, 100.0 gain | Question 1: What is the part number of the PXI-6025E?