img

1859.59

The SCXI-1125 is a voltage input module with 8 analog channels, 300 Vrms isolation, and requires NI-DAQmx 9.0 or later.

In Stock | Ships Today

img

    Description

    The Part Number for this product is 776872-25, which falls under the Category of SCXI & Legacy. Specifically, the Model in question is the SCXI-1125, known as the Description SCXI-1125 Voltage Input Module. This module boasts a Working Isolation of 300 Vrms, making it a safe and reliable choice for various applications.

    It comes equipped with 8 Analog Input Channels, providing ample connectivity for multiple signals. The Output Range of ±5.0 V ensures compatibility with a wide range of sensors and transducers. Furthermore, the physical attributes of this module, including a Weight of 22.6 oz and Dimensions of 7.4 x 6.8 x 1.2 in, make it a compact and manageable addition to any setup.

    The module also features Low Pass Filter Configurations of either 4 Hz or 10 kHz, providing flexibility in signal processing. It requires software version NI-DAQmx 9.0 or later for operation, ensuring compatibility with modern software environments. Additionally, it is compatible with Application Development Environments (ADEs) such as LabVIEW, LabWindows/CVI, and Measurement Studio, offering a versatile range of programming options.

    Calibration services are available, including options for NIST accredited calibrations through a 3rd party, as well as in-house calibration to manufacturer specifications, ensuring accurate and reliable measurements. Lastly, the End of Life Status has been announced, but it remains available for purchase and repairs by Apex Waves, providing continued support for existing users.

    Specification Detail
    Part Number 776872-25
    Category SCXI & Legacy
    Model SCXI-1125
    Description SCXI-1125 Voltage Input Module
    Working Isolation 300 Vrms
    Channels 8 Analog Input Channels
    Output Range ±5.0 V
    Weight 22.6 oz
    Dimensions 7.4 x 6.8 x 1.2 in
    Low Pass Filter Configurations 4 Hz or 10 kHz
    Software Requirement NI-DAQmx 9.0 or later
    Compatible ADEs LabVIEW, LabWindows/CVI, Measurement Studio
    Calibration Available, NIST accredited calibrations through a 3rd party, in-house calibration to manufacturer specifications
    End of Life Status Announced, available for purchase and repairs by Apex Waves

    Question 1: What is the part number for the SCXI-1125?
    Answer 1: 776872-25

    Question 2: How many analog input channels does the SCXI-1125 have?
    Answer 2: 8 channels

    Question 3: What is the output range of the SCXI-1125?
    Answer 3: ±5.0 V

    Question 4: What software version is required for the SCXI-1125?
    Answer 4: NI-DAQmx 9.0 or later

    Question 5: Is calibration available for the SCXI-1125?
    Answer 5: Yes, including NIST accredited options