186055B-01

The PXI-5600 RF Downconverter operates from 9 kHz to 2.7 GHz with a 20 MHz real-time bandwidth and exceptional noise performance.

In Stock | Ships Today

img

    Description

    The Part Number 778283-01 belongs to the category of RF Downconverters, specifically the model PXI-5600. It boasts a Real-time Bandwidth Capacity of 20 MHz, making it suitable for a wide range of applications. The device operates across a frequency range from 9 kHz to 2.7 GHz, offering versatility in usage.

    Its Noise Density is exceptionally low, at less than -140 dBm/Hz, ensuring clear signal processing. The Spurious-free Dynamic Range is greater than 80 dB, providing high-quality signal fidelity. Moreover, the Phase Noise performance is excellent, with less than -94 dBc/Hz at a 10 kHz offset.

    The Frequency Stability (Timebase) of the PXI-5600 is ±20 parts per billion (ppb), and its Frequency Accuracy (Timebase) is within ±50 ppb, indicating a high degree of precision in frequency measurements. To operate, the device requires software such as NI-RFSA 2.1, NIPXI-5600 Support, LabVIEW, LabWindows/CVI, and Microsoft C/C++.

    Connectivity options for the PXI-5600 are comprehensive, including Connectors for FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, and INPUT, facilitating easy integration into a variety of setups. It is recommended to allow a Warm-up Time of 20 minutes for optimal performance. The device should undergo calibration either Annually or every two years to maintain accuracy and reliability.

    Specification Detail
    Part Number 778283-01
    Category RF Downconverters
    Model PXI-5600
    Real-time Bandwidth Capacity 20 MHz
    Operating Range 9 kHz to 2.7 GHz
    Noise Density < -140 dBm/Hz
    Spurious-free Dynamic Range > 80 dB
    Phase Noise < -94 dBc/Hz at 10 kHz offset
    Frequency Stability (Timebase) ±20 ppb
    Frequency Accuracy (Timebase) ±50 ppb
    Software Requirements NI-RFSA 2.1, NIPXI-5600 Support, LabVIEW, LabWindows/CVI, Microsoft C/C++
    Connectors FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, INPUT
    Recommended Warm-up Time 20 minutes
    Calibration Period Annually or every two years
    Real-time Bandwidth Question 1: What is the frequency range of the PXI-5600?
    Answer 1: 9 kHz to 2.7 GHz

    Question 2: What is the real-time bandwidth of the PXI-5600?
    Answer 2: 20 MHz

    Question 3: What is the noise density of the PXI-5600?
    Answer 3: < -140 dBm/Hz Question 4: How often should the PXI-5600 be calibrated?
    Answer 4: Annually or every two years

    Question 5: What is the phase noise at 10 kHz offset for PXI-5600?
    Answer 5: < -94 dBc/Hz