The PXI-5600 is an RF downconverter with 20 MHz bandwidth, 9 kHz to 2.7 GHz frequency range, and supports various software including LabVIEW.

In Stock | Ships Today

img

    Description

    The Part Number 778283-01 refers to a Model PXI-5600, which is categorized under RF Downconverters. This model is designed to operate with a Real-Time Bandwidth of 20 MHz, making it suitable for a wide range of RF applications. The Frequency Range of the PXI-5600 extends from 9 kHz to 2.7 GHz, providing a versatile range for different use-cases.

    One of the key features of this model is its Average Noise Density, which is less than -140 dBm/Hz, ensuring a clean signal processing environment. Additionally, the Spurious-Free Dynamic Range is greater than 80 dB, which is indicative of the device’s ability to handle high dynamic range signals without introducing spurious emissions. The Phase Noise performance is exceptional, with less than -94 dBc/Hz at 10 kHz offset, ensuring low phase noise in signal processing.

    The Timebase Stability is rated at ±20 ppb, and the Timebase Accuracy at ±50 ppb, which are critical specifications for applications requiring precise timing and frequency accuracy. The Input Signal Repeatability is within 0.2 dB, highlighting the device’s reliability in delivering consistent performance.

    Compatibility with various software platforms is essential for modern RF downconverters. The PXI-5600 supports NI-RFSA 2.1, NIPXI-5600 Support, LabVIEW, LabWindows/CVI, Microsoft C/C++, making it versatile in different development environments. The Connectors include FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, INPUT, providing a comprehensive array of connectivity options for various RF setups.

    To ensure optimal performance, a Recommended Warm-up Time of 20 minutes is suggested before use. Additionally

    Specification Detail
    Part Number 778283-01
    Model PXI-5600
    Category RF Downconverters
    Real-Time Bandwidth 20 MHz
    Frequency Range 9 kHz to 2.7 GHz
    Average Noise Density < -140 dBm/Hz
    Spurious-Free Dynamic Range > 80 dB
    Phase Noise < -94 dBc/Hz at 10 kHz offset
    Timebase Stability ±20 ppb
    Timebase Accuracy ±50 ppb
    Input Signal Repeatability < 0.2 dB
    Software Compatibility NI-RFSA 2.1, NIPXI-5600 Support, LabVIEW, LabWindows/CVI, Microsoft C/C++
    Connectors FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, INPUT
    Recommended Warm-up Time 20 minutes
    Calibration Period Annually

    Question 1: What’s the bandwidth of the PXI-5600?
    Answer 1: 20 MHz

    Question 2: What frequency range does the PXI-5600 cover?
    Answer 2: 9 kHz to 2.7 GHz

    Question 3: What is the average noise density of the PXI-5600?
    Answer 3: <-140 dBm/Hz Question 4: What’s the warm-up time recommended for PXI-5600?
    Answer 4: 20 minutes

    Question 5: Does the PXI-5600 support LabVIEW software?
    Answer 5: Yes