Description
The product with the part number 186676C-04 falls under the category of PXI Switches and is identified by the model SCXI-1192. This particular model is an 8 Channel SPDT, 18 GHz, 50 Ohm, RF Relay Module, designed to operate within a frequency range of up to 18 GHz. It features 8 SPDT relays, each with 2 channels, allowing for versatile application in various setups.
The module is engineered to handle a maximum rated voltage of 30 V and a maximum rated current of 2 A at 30 V. Connectivity is facilitated through 24 screw-on SMA jacks, ensuring secure and reliable connections. The contacts within the module are made from gold plate, which enhances their durability and performance. It utilizes latching electromechanical relays for its operation, ensuring that there is no defined power-up state; it maintains its state even in case of power loss.
Regarding its configuration, the rest mode connection is NC to COM for every relay, which adds to the module’s reliability and ease of use. This module is highly compatible with systems that require routing signals from two RF sources to a single RF measurement instrument, such as a Scope, Spectrum Analyzer, or Power Meter, making it an indispensable tool for professionals in the field.
The obsolescence status of this product has been announced by National Instruments; however, it remains available for purchase and repairs by the manufacturer. This ensures that users of this component can continue to rely on its performance and support for their critical applications.
| Specification | Detail |
|---|---|
| Part Number | 186676C-04 |
| Category | PXI Switches |
| Model | SCXI-1192 |
| Description | 8 Channel SPDT, 18 GHz, 50 Ohm, RF Relay Module |
| Frequency Range | Up to 18 GHz |
| Number of Channels | 8 SPDT relays with 2 channels per relay |
| Max Rated Voltage | 30 V |
| Max Rated Current | 2 A at 30 V |
| Connector Type | 24 screw-on SMA jacks |
| Contact Material | Gold plate |
| Relay Type | Latching electromechanical relays |
| Power-up State | No defined power-up state; maintains state in case of power loss |
| Rest Mode Connection | NC to COM for every relay |
| Compatibility | Can route signals from two RF sources to a single RF measurement instrument (Scope, Spectrum Analyzer, Power Meter) |
| Obsolescence Status | Announced by National Instruments; available for purchase and repairs by
Question 1: What is the part number for the PXI Switch? Question 2: How many GHz does the SCXI-1192 support? Question 3: How many channels does the SCXI-1192 have? Question 4: What connector type does the SCXI-1192 use? Question 5: Is the SCXI-1192 obsolescence announced? |