img

186679A-01

The SCXI-1191, part number 186679A-01, is a PXI Switch with SPDT configuration, DC to 4 GHz bandwidth, designed for multiplexed operations.

In Stock | Ships Today

img

    Description

    The product with the Part Number 186679A-01 is categorized under PXI Switches and is identified by the model SCXI-1191. This particular model features a Switch Configuration of Single-Pole Double-Throw, making it versatile for various applications. It boasts a Bandwidth capability from DC to 4 GHz, ensuring a broad range of signal frequencies can be handled efficiently.

    Regarding its electrical specifications, the SCXI-1191 can operate at a Maximum Rated Voltage of 30 V and supports a Maximum Rated Current of 0.33 A at 30 V. Its design allows for Operational Mode in a Multiplexed manner, providing flexibility in how it can be utilized within a system.

    This device is designed to be compatible with PXI Chassis models PXI-1010 and PXI-1011, ensuring a seamless integration into existing systems. Additionally, it facilitates a straightforward Connection to DAQ systems, as no external cabling is required for connection to PXI multifunction I/O modules. Management and removal of the device from software systems are streamlined through the use of Measurement & Automation Explorer.

    It is important to note that the Obsolete Status of the SCXI-1191 has been announced by National Instruments. However, it remains available for purchase through Apex Waves, providing an avenue for acquiring this capable and versatile PXI Switch model.

    Specification Detail
    Part Number 186679A-01
    Category PXI Switches
    Model SCXI-1191
    Switch Configuration Single-Pole Double-Throw
    Bandwidth DC to 4 GHz
    Maximum Rated Voltage 30 V
    Maximum Rated Current 0.33 A at 30 V
    Operational Mode Multiplexed
    Compatible Chassis PXI-1010, PXI-1011
    Connection to DAQ No external cabling required for connection to PXI multifunction I/O module
    Removal from Software Via Measurement & Automation Explorer
    Obsolete Status Announced by National Instruments, available from Apex Waves

    Question 1: What is the bandwidth of SCXI-1191?
    Answer 1: DC to 4 GHz

    Question 2: What is the switch configuration of SCXI-1191?
    Answer 2: SPDT

    Question 3: What is the maximum rated voltage of SCXI-1191?
    Answer 3: 30 V

    Question 4: Can SCXI-1191 be used with PXI-1010 and PXI-1011 chassis?
    Answer 4: Yes

    Question 5: Is the SCXI-1191 obsolete?
    Answer 5: Yes, but available at Apex Waves