Description
The part number for this specific piece of hardware is 186729A-01 (777318-502), indicating a unique identifier for this model. This product falls under the Compact FieldPoint category, which signifies its compatibility and design for compact field deployment. Specifically, the model in question is the cFP-CTR-502.
The National Instruments cFP-CTR-502 Counter Module for Compact Fieldpoint is designed to provide efficient and reliable counting functionalities in a compact form factor. It stands out due to its ability to maintain a very low leakage current in the OFF state, ensuring only a minimal amount of current flows when it is not in active use.
Each channel on this device can handle a maximum load current of 1 A, which allows for robust performance in various applications. Users have the flexibility to configure each count input channel with specific attributes and commands through the FieldPoint software, enhancing the module’s adaptability to different operational requirements.
The terminal count range for this unit spans from 0 to 65,535, with the default terminal count set at 65,535. Upon reaching the terminal count, the device automatically resets the count to 0 and triggers any associated outputs, ensuring seamless operation and integration into automated processes.
An external gate input feature enables or disables counting based on the signal’s state; counting is enabled when the signal is high and disabled when low. Furthermore, users have the option to configure the count input channel to either not count at all or to count continuously without the need for an external gate input, with the default setting being Always Enabled. This provides additional flexibility in how the module can be used in various counting applications.
| Specification | Detail |
|---|---|
| Part Number | 186729A-01 (777318-502) |
| Category | Compact FieldPoint |
| Model | cFP-CTR-502 |
| Description | National Instruments cFP-CTR-502 Counter Module for Compact Fieldpoint |
| Leakage Current | In OFF state, allows only a small leakage current to flow |
| Maximum Load Current per Channel | 1 A |
| Configuration in FieldPoint Software | Each count input channel can be configured with specific attributes and commands |
| Terminal Count Range | 0 to 65,535 |
| Default Terminal Count | 65,535 |
| Behavior at Terminal Count | Resets count to 0 and triggers any associated outputs |
| External Gate Input | Counting enabled when signal is high; disabled when signal is low |
| Always Disabled/Enabled Option | User can select for the count input channel to not count or to count continuously without an external gate input. Default: Always Enabled |
Question 1: What is the part number for the cFP-CTR-502?
Answer 1: 186729A-01 (777318-502)
Question 2: What category does the cFP-CTR-502 belong to?
Answer 2: Compact FieldPoint
Question 3: What is the terminal count range of the cFP-CTR-502?
Answer 3: 0 to 65,535
Question 4: What is the maximum load current per channel on the cFP-CTR-502?
Answer 4: 1 A
Question 5: Can the cFP-CTR-502 count input be always enabled?
Answer 5: Yes, it can be set to Always Enabled