img

186729C-02

The cFP-CTR-502 is a configurable Compact FieldPoint Counter Input Module with a terminal count range of 0 to 65,535, allowing minimal leakage current.

In Stock | Ships Today

img

    Description

    The Compact FieldPoint part number 186729C-02 (777318-502) is a specialized counter input module, model cFP-CTR-502. This module is designed for precise counting applications and offers a range of technical specifications catering to various industrial needs.

    The module’s core function is to serve as a Counter Input Module, which permits only a small leakage current in the OFF state, ensuring efficient power usage and safety. For operational limits, it has a load current limit that does not exceed 1 A per channel, safeguarding the module and connected devices from potential overcurrent damage.

    One of the key features of this module is its configurability via FieldPoint software, which allows for flexible setup and adjustments according to specific counting tasks. The terminal count range of this module extends from 0 to 65,535, with a default terminal count value set at 65,535, offering a wide range for counting applications.

    Additionally, the cFP-CTR-502 supports an optional external gate input, which influences counting, providing users with the option to control counting operations dynamically. This feature is complemented by the ability to configure the module to be always enabled or disabled, allowing for continuous counting or no counting without gate input, based on the application’s requirements. The default gate input mode is set to Always Enabled, facilitating immediate use in most scenarios.

    Overall, the cFP-CTR-502 Counter Input Module is a versatile and configurable solution for numerous counting applications, designed to meet the demanding requirements of industrial environments.

    Specification Detail
    Part Number 186729C-02 (777318-502)
    Category Compact FieldPoint
    Model cFP-CTR-502
    Description Counter Input Module
    Leakage Current Permits only a small leakage current in OFF state
    Load Current Limit Not over 1 A per channel
    Configuration Configurable via FieldPoint software
    Terminal Count Range 0 to 65,535
    Default Terminal Count Value 65,535
    External Gate Input Optional; influences counting
    Always Enabled/Disabled Option for continuous counting or no counting without gate input
    Default Gate Input Mode Always Enabled

    Question 1: What is the terminal count range of cFP-CTR-502?
    Answer 1: 0 to 65,535

    Question 2: What minimal leakage current condition does cFP-CTR-502 ensure?
    Answer 2: Minimal leakage in OFF state

    Question 3: Can the cFP-CTR-502 be configured for counting tasks?
    Answer 3: Yes, via FieldPoint software

    Question 4: What is the load current limit for each channel on cFP-CTR-502?
    Answer 4: 1 A per channel

    Question 5: Does cFP-CTR-502 support an external gate input?
    Answer 5: Yes, with optional input for dynamic control