Description
The Compact FieldPoint part number 186729C-02 (777318-502) is a specialized counter input module, model cFP-CTR-502. This module is designed for precise counting applications and offers a range of technical specifications catering to various industrial needs.
The module’s core function is to serve as a Counter Input Module, which permits only a small leakage current in the OFF state, ensuring efficient power usage and safety. For operational limits, it has a load current limit that does not exceed 1 A per channel, safeguarding the module and connected devices from potential overcurrent damage.
One of the key features of this module is its configurability via FieldPoint software, which allows for flexible setup and adjustments according to specific counting tasks. The terminal count range of this module extends from 0 to 65,535, with a default terminal count value set at 65,535, offering a wide range for counting applications.
Additionally, the cFP-CTR-502 supports an optional external gate input, which influences counting, providing users with the option to control counting operations dynamically. This feature is complemented by the ability to configure the module to be always enabled or disabled, allowing for continuous counting or no counting without gate input, based on the application’s requirements. The default gate input mode is set to Always Enabled, facilitating immediate use in most scenarios.
Overall, the cFP-CTR-502 Counter Input Module is a versatile and configurable solution for numerous counting applications, designed to meet the demanding requirements of industrial environments.
| Specification | Detail |
|---|---|
| Part Number | 186729C-02 (777318-502) |
| Category | Compact FieldPoint |
| Model | cFP-CTR-502 |
| Description | Counter Input Module |
| Leakage Current | Permits only a small leakage current in OFF state |
| Load Current Limit | Not over 1 A per channel |
| Configuration | Configurable via FieldPoint software |
| Terminal Count Range | 0 to 65,535 |
| Default Terminal Count Value | 65,535 |
| External Gate Input | Optional; influences counting |
| Always Enabled/Disabled | Option for continuous counting or no counting without gate input |
| Default Gate Input Mode | Always Enabled |
Question 1: What is the terminal count range of cFP-CTR-502?
Answer 1: 0 to 65,535
Question 2: What minimal leakage current condition does cFP-CTR-502 ensure?
Answer 2: Minimal leakage in OFF state
Question 3: Can the cFP-CTR-502 be configured for counting tasks?
Answer 3: Yes, via FieldPoint software
Question 4: What is the load current limit for each channel on cFP-CTR-502?
Answer 4: 1 A per channel
Question 5: Does cFP-CTR-502 support an external gate input?
Answer 5: Yes, with optional input for dynamic control