Description
The Part Number 776572-29 refers to a high-quality PXI Switch under the category of SCXI-1129. This particular model, SCXI-1129, is described as a CCA, SCXI-1129 BASE, Matrix/Multiplexer Switch Module, designed to facilitate complex switching arrangements in testing and measurement setups.
The Matrix Configuration of this switch module is highly versatile, allowing for a maximum setup of a 4 x 64, 2-wire switch matrix. Additionally, it can function as four separate 4 x 16, two 4 x 32, or two 8 x 16, 2-wire matrixes, providing flexibility for various testing scenarios. The Maximum Scan Rate achievable with this module is 100 crosspoints per second, ensuring efficient performance in rapid switching applications.
One of the critical specifications of this switch module is its Thermal Offset, which is less than 9 µV, ensuring minimal signal distortion due to thermal variations. The module supports various Relay Types, including electromechanical, latching, and nonlatching, thereby accommodating a wide range of switching needs.
Compatible Terminal Blocks for this module include SCXI-1336, SCXI-1333, SCXI-1335, SCXI-1337, SCXI-1334, and SCXI-1339, providing users with multiple options for connectivity. Software Compatibility is extensive, with support for NI-SWITCH, NI-DMM, and programmability via LabVIEW, Measurements Studio, Visual Basic, allowing for easy integration into existing systems.
The physical dimensions of the SCXI-1129 are noted as 7.8 x 1.2 x 6.8 inches, and it weighs 1 lb., making it compact and lightweight for easy installation in various setups. Despite its Obsolete Status, as announced by National Instruments, it remains available for purchase and repairs via Apex Waves, ensuring continued support for users of this sophisticated switch module.
| Specification | Detail |
|---|---|
| Part Number | 776572-29 |
| Category | PXI Switches |
| Model | SCXI-1129 |
| Description | CCA, SCXI-1129 BASE, Matrix/Multiplexer Switch Module |
| Matrix Configuration | 4 x 64, 2-wire switch matrix (max); Can function as four 4 x 16, two 4 x 32, or two 8 x 16, 2-wire matrixes |
| Maximum Scan Rate | 100 crosspoints per second |
| Thermal Offset | < 9 µV |
| Relay Types | Electromechanical, latching, nonlatching |
| Compatible Terminal Blocks | SCXI-1336, SCXI-1333, SCXI-1335, SCXI-1337, SCXI-1334, SCXI-1339 |
| Software Compatibility | NI-SWITCH, NI-DMM; Programmable via LabVIEW, Measurements Studio, Visual Basic |
| Dimensions | 7.8 x 1.2 x 6.8 in. |
| Weight | 1 lb. |
| Obsolete Status | Announced by National Instruments; Available for purchase and repairs by Apex Waves |
Question 1: What is the part number for the SCXI-1129 PXI Switch?
Answer 1: 776572-29
Question 2: What is the maximum setup configuration for SCXI-1129?
Answer 2: 4×64 2-wire matrix
Question 3: What is the maximum scan rate of SCXI-1129?
Answer 3: 100 crosspoints/sec
Question 4: What software is SCXI-1129 compatible with?
Answer 4: NI-SWITCH, NI-DMM, LabVIEW
Question 5: Is the SCXI-1129 still available despite being obsolete?
Answer 5: Yes, through Apex Waves