Description
The PXI-4472 is a high-performance model within the PXI DSA (Dynamic Signal Analyzer) category. This model boasts a substantial 24-bit resolution, ensuring precise data acquisition and analysis. With a sample rate of up to 102.4 kS/s, it can accurately capture rapid changes in signal without missing critical information.
Designed to accommodate a variety of testing and measurement needs, the PXI-4472 features 8 inputs, making it versatile for multiple signal analysis applications. Its dynamic range of 110 dB and frequency accuracy of 25 ppm highlight its ability to deliver reliable and accurate measurements, even in demanding environments.
The device is capable of handling an input signal range of up to 10 Vpk, ensuring a broad array of signals can be analyzed with precision. Connectivity is facilitated through SMB male analog I/O and SMB male digital trigger connectors, providing flexibility in setup and integration into existing systems.
Despite its advanced features, the PXI-4472 has been announced as obsolete, indicating that it may no longer be in production. However, calibration services remain available, including options for NIST accredited calibrations through a third party or basic in-house calibration, ensuring the device can continue to provide accurate readings.
Its part numbers, 187123R-04L, 778279-01, and 187123M-01L, identify the various configurations of the PXI-4472, accommodating specific requirements and applications, thereby reinforcing its adaptability and utility in a wide range of professional settings.
| Specification | Detail |
|---|---|
| Model | PXI-4472 |
| Part Number | 187123R-04L, 778279-01, 187123M-01L |
| Category | PXI DSA (Dynamic Signal Analyzer) |
| Resolution | 24 Bit |
| Sample Rate | 102.4 kS/s |
| Number of Inputs | 8 |
| Dynamic Range | 110 dB |
| Frequency Accuracy | 25 ppm |
| Input Signal Range | 10 Vpk |
| Connectors | SMB male analog I/O, SMB male digital trigger |
| Obsolete Status | Announced |
| Calibration | Available, with options for NIST accredited calibrations through a 3rd party or basic in-house calibration |
Question 1: What is the resolution of the PXI-4472?
Answer 1: 24-bit
Question 2: What sample rate does the PXI-4472 support?
Answer 2: 102.4 kS/s
Question 3: How many inputs does the PXI-4472 have?
Answer 3: 8 inputs
Question 4: What is the dynamic range of the PXI-4472?
Answer 4: 110 dB
Question 5: Is the PXI-4472 still in production?
Answer 5: No, it has been announced as obsolete.