img

187227C-03

The PXI-6115 offers 4 differential input channels with 12-bit resolution and a max sample rate of 10 MS/s/channel, alongside 2 analog outputs and 8 DIO lines.

In Stock | Ships Today

img

    Description

    The PXI-6115 is a multifaceted data acquisition device designed to cater to a wide range of applications. It is available under several part numbers, including 187227K-01, 187227H-01, 187227R-03, 778194-01, and 778204-01. This device boasts 4 differential analog input channels with a 12-bit resolution, ensuring precise data acquisition. It is capable of a maximum sample rate of 10 MS/s per channel, providing quick and efficient data processing.

    Additionally, the PXI-6115 features 2 analog output channels and 8 digital I/O lines, enhancing its versatility in interfacing with various sensors and actuators. The analog input FIFO buffer size varies, with 16 MS for the 778194-01 model and 32 MS for the 778204-01 model, allowing for extensive data collection and storage.

    Users have a wide range of input ranges to choose from, spanning from 0.2 to 42 V, accommodating a broad spectrum of signals. The device is equipped with two 3-pole Bessel analog filters, with cutoff frequencies of 50 kHz and 500 kHz, ensuring signal integrity by reducing high-frequency noise. It also includes two 24-bit counter/timers, further expanding its utility in complex measurement and control tasks.

    The PXI-6115 uses a 68-pin male SCSI I/O connector for connectivity, ensuring a reliable and secure connection to peripheral devices. A recommended warm-up time of 15 minutes is advised for optimal performance. To maintain accuracy and reliability, a calibration interval of at least once a year is recommended. Calibration options include NIST accredited calibrations through a 3rd party, as well as basic (unaccredited) in-house calibration, offering flexibility in maintenance routines.

    With physical dimensions of 6.3 x 3.9 in., this device is compact and easily integrated into a variety of setups.

    Feature Description
    Part Numbers 187227K-01, 187227H-01, 187227R-03, 778194-01, 778204-01
    Model PXI-6115
    Analog Input Channels 4 differential, 12-bit resolution
    Maximum Sample Rate 10 MS/s/channel
    Analog Output Channels 2
    Digital I/O Lines 8
    Analog Input FIFO Buffer Size 16 MS (778194-01), 32 MS (778204-01)
    Input Ranges 0.2 to 42 V
    Analog Filters 2 (3-pole Bessel, 50 kHz and 500 kHz)
    Counter/Timers Two 24-bit
    Connector 68-pin male SCSI I/O connector
    Recommended Warm-Up Time 15 minutes
    Calibration Interval At least once a year
    Physical Dimensions 6.3 x 3.9 in.
    Operating Temperature Range 0 °C to 50 °C
    Storage Temperature Range -20 °C to 70 °C
    NI Maintenance Phase Start Date December 30, 2022
    Calibration Options NIST accredited calibrations through a 3rd party; basic (unaccredited) in-house calibration
    Question 1: What is the resolution of the PXI-6115’s input channels?
    Answer 1: 12-bit

    Question 2: How many DIO lines does the PXI-6115 have?
    Answer 2: 8 digital I/O lines

    Question 3: What is the max sample rate per channel on the PXI-6115?
    Answer 3: 10 MS/s

    Question 4: What type of connector does the PXI-6115 use?
    Answer 4: 68-pin male SCSI I/O connector

    Question 5: What’s the recommended warm-up time for PXI-6115?
    Answer 5: 15 minutes