Description
“`html
The PXI-6115 features a variety of specifications that make it a versatile choice for a wide range of applications. With part numbers including 187227K-01, 187227H-01, 187227R-03, 778194-01, and 778204-01, it provides multiple options for system integration.
The analog input channels consist of 4 differential inputs, ensuring precise data acquisition. The device boasts a resolution of 12 bit, allowing for accurate signal representation. The maximum sample rate is an impressive 10 MS/s per channel, suitable for high-speed measurements.
Additionally, the PXI-6115 offers 2 analog output channels and 8 digital I/O lines, enhancing its functionality in various test and measurement setups. The analog input FIFO buffer size varies, with 16 MS available for the 778194-01 model and 32 MS for the 778204-01, providing ample data storage for intensive applications.
The device supports input ranges from 0.2 to 42 V, accommodating a wide array of signal amplitudes. It also includes two 24-bit counter/timers and two analog filters with 3-pole Bessel configurations, frequencies at 50 kHz, and 500 kHz, for refined signal processing capabilities.
For optimal performance, a recommended warm-up time of 15 minutes is advised, and a calibration period of at least once a year is recommended to maintain accuracy. Its physical dimensions are compact, measuring 6.3 x 3.9 inches, making it a suitable fit for most setups. The operating temperature range starts from 0 °C, ensuring reliable operation in various environmental conditions.
“`
| Specification | Details |
|---|---|
| Part Numbers | 187227K-01, 187227H-01, 187227R-03, 778194-01, 778204-01 |
| Model | PXI-6115 |
| Analog Input Channels | 4 differential |
| Resolution | 12 bit |
| Maximum Sample Rate | 10 MS/s/channel |
| Analog Output Channels | 2 |
| Digital I/O Lines | 8 |
| Analog Input FIFO Buffer Size | 16 MS (778194-01), 32 MS (778204-01) |
| Input Ranges | 0.2 to 42 V |
| Counter/Timers | Two 24-bit |
| Analog Filters | 2 (3-pole Bessel), Frequencies: 50 kHz, 500 kHz |
| Recommended Warm-up Time | 15 minutes |
| Calibration Period | At least once a year |
| Physical Dimensions | 6.3 x 3.9 inches |
| Operating Temperature Range | 0 °C
Question 1: What is the maximum sample rate per channel of the PXI-6115? Question 2: How many analog input channels does the PXI-6115 have? Question 3: What are the analog input FIFO buffer sizes for models 778194-01 and 778204-01? Question 4: What is the resolution of the PXI-6115? Question 5: What recommended warm-up time does the PXI-6115 have? |