    Description

    The PXI-6115 is a high-performance data acquisition card encapsulated with a variety of features designed for versatile applications. It is identified by multiple Part Numbers including 187227K-01, 187227H-01, 187227R-03, 778194-01, and 778204-01, making it accessible for a wide range of system requirements.

    This model provides 4 differential Analog Input Channels with a 12 bit resolution, ensuring precise data collection. It boasts a Maximum Sample Rate of 10 MS/s per channel, which facilitates the capture of fast transient signals without compromising the integrity of the data. In addition to its input capabilities, the PXI-6115 offers 2 Analog Output Channels and 8 Digital I/O Lines, enhancing its versatility in interfacing with various sensors and actuators.

    The device is equipped with an Analog Input FIFO Buffer Size of 16 MS for the 778194-01 model and 32 MS for the 778204-01 model, providing ample buffer capacity for high-speed data acquisition tasks. It supports a wide range of Input Ranges from 0.2 to 42 V, accommodating various signal amplitudes.

    Incorporated within the PXI-6115 are 3-pole Bessel Analog Filters with cutoff frequencies of 50 kHz and 500 kHz, effectively minimizing signal distortion and noise. It also features Two 24-bit Counter/Timers, expanding its functionality in time-based measurements and control applications.

    The device utilizes a 68-pin male SCSI I/O connector and SMB connectors for robust and reliable connectivity. A Recommended Warm-up Time of 15 minutes is suggested for optimal performance stability. To maintain accuracy and reliability, a Calibration Interval of at least once a year is recommended. Lastly, its Physical Dimensions are compact, measuring at

    Specification Detail
    Part Numbers 187227K-01, 187227H-01, 187227R-03, 778194-01, 778204-01
    Model PXI-6115
    Analog Input Channels 4 differential
    Resolution 12 bit
    Maximum Sample Rate 10 MS/s/channel
    Analog Output Channels 2
    Digital I/O Lines 8
    Analog Input FIFO Buffer Size 16 MS (778194-01), 32 MS (778204-01)
    Input Ranges 0.2 to 42 V
    Analog Filters 3-pole Bessel (50 kHz, 500 kHz)
    Counter/Timers Two 24-bit
    Connector Type 68-pin male SCSI I/O connector, SMB connectors
    Recommended Warm-up Time 15 minutes
    Calibration Interval At least once a year
    Physical Dimensions 6.3 x 3.9 in

    Question 1: How many analog input channels does PXI-6115 have?
    Answer 1: 4 differential channels

    Question 2: What is the max sample rate of PXI-6115?
    Answer 2: 10 MS/s per channel

    Question 3: What are the analog filter cutoff frequencies of PXI-6115?
    Answer 3: 50 kHz and 500 kHz

    Question 4: What type of connector does PXI-6115 use?
    Answer 4: 68-pin male SCSI and SMB connectors

    Question 5: What is the recommended calibration interval for PXI-6115?
    Answer 5: At least once a year