Description
“`html
The product with part numbers 187275B-01L, 777687-36 is categorized under PXI Switches and is model SCXI-1336. This particular model boasts a configuration of a 16×16 (2-wire) matrix, designed for versatile switching needs.
It is compatible with the SCXI-1129 switch module, ensuring seamless integration for users. For connectivity, it offers direct connectivity of signal wires to screw terminals, along with two 128-pin DIN connectors for efficient column interfacing. Expansion capabilities are robust, utilizing a matrix expansion cable for instant row extension and allowing matrix extension wires for further column expansion.
The product adheres to the safety directive 73/23/EEC, and the EMC directive 89/336/EEC, ensuring compliance with European standards. Additional features include connections for scanner digital outputs and external input trigger signals, enhancing its utility.
Installation and maintenance require specific tools such as an SCXI chassis, a 1/8 in. flathead screwdriver, numbers 1 and 2 Phillips screwdrivers, long-nose pliers, a wire cutter, a wire insulation stripper, and a matrix expansion plug.
A voltage warning is issued, indicating that hazardous voltages (>42.4 Vpk/60 VDC) must not be connected to any relay terminal when safety low-voltage (≤42.4 Vpk/60 VDC) is present, to ensure user safety.
The product is currently in Obsolete Status, which may affect availability and support options.
“`
| Specification | Details |
|---|---|
| Part Number | 187275B-01L, 777687-36 |
| Category | PXI Switches |
| Model | SCXI-1336 |
| Configuration | 16×16 (2-wire) matrix |
| Compatibility | SCXI-1129 switch module |
| Connectivity | Direct connectivity of signal wires to screw terminals, two 128-pin DIN connectors for column interfacing |
| Expansion | Utilizes matrix expansion cable for instant row extension, allows matrix extension wires for column expansion |
| Safety Directive | 73/23/EEC |
| EMC Directive | 89/336/EEC |
| Additional Features | Connections for scanner digital outputs and external input trigger signals |
| Tools Required | SCXI chassis, 1/8 in. flathead screwdriver, numbers 1 and 2 Phillips screwdrivers, long-nose pliers, wire cutter, wire insulation stripper, matrix expansion plug |
| Voltage Warning | Hazardous voltages (>42.4 Vpk/60 VDC) must not be connected to any relay terminal when safety low-voltage (≤42.4 Vpk/60 VDC) is present |
| Obsolete Status
Question 1: What is the part number for the SCXI-1336? Question 2: How is the SCXI-1336 compatible with? Question 3: What type of connectors does the SCXI-1336 use? Question 4: What voltage should not be exceeded for safety? Question 5: Is the SCXI-1336 still in production? |