Description
The Parallel Digital Frame Grabber Device is available in two part numbers: 777662-01 RS-422/TTL and 777662-02 LVDS/TTL. This device boasts a significant 32-Bit resolution, ensuring high-quality image capture and processing. It is designed to be a high-performance device with a 16 MB memory that is expandable, catering to various application needs.
Operating at a clock speed of 50 MHz, the device can achieve an impressive acquisition rate of 200 MB/s, making it suitable for high-speed data capture. Compatibility is a key feature of this device, supporting a wide range of software including NI Vision Acquisition Software 8.0 or later, LabVIEW, LabWindows/CVI, Microsoft Visual Basic, NI Vision Builder for Automated Inspection, NI Vision Development Module, and Measurement Studio. Additionally, it is compatible with the NI-IMAQ driver, ensuring ease of integration with existing systems.
The device features a 100-pin SCSI type I/O connector, providing reliable and robust connectivity options. Furthermore, it offers dual clock outputs, ranging from 500 kHz to 50 MHz, for versatile synchronization capabilities. An integrated RS232 Serial Interface enhances its connectivity options, making it adaptable to various communication requirements.
For customized image processing, the device includes four 8-bit or two 16-bit LUTs (Lookup Tables), allowing for detailed and adjustable image manipulation. It also supports up to 4 external trigger I/O lines, operating at 0 V to 5 V (TTL), which enables synchronized acquisition across multiple devices or sensors.
Despite its advanced features, the device maintains a compact and lightweight design, weighing just 0.5 lbs. This makes it an ideal choice for applications where space is at a premium, without compromising on performance or functionality.
| Specification | Details |
|---|---|
| Part Numbers | 777662-01 RS-422/TTL, 777662-02 LVDS/TTL |
| Resolution | 32-Bit |
| Type | Parallel Digital Frame Grabber Device |
| Memory | 16 MB (expandable) |
| Clock Speed | 50 MHz |
| Acquisition Rate | 200 MB/s |
| Software Compatibility | NI Vision Acquisition Software 8.0 or later, LabVIEW, LabWindows/CVI, Microsoft Visual Basic, NI Vision Builder for Automated Inspection, NI Vision Development Module, Measurement Studio |
| Driver Compatibility | NI-IMAQ |
| Connector Type | 100-pin SCSI type I/O connector |
| Clock Outputs | Dual, 500 kHz to 50 MHz |
| RS232 Serial Interface | Yes |
| LUTs (Lookup Tables) | Four 8-bit or two 16-bit |
| External Trigger I/O Lines | Up to 4, 0 V to 5 V (TTL) |
| Weight | 0.5 lbs |
| Dimensions
Question 1: What clock speed does the PCI-1424 operate at? Answer 1: 50 MHz Question 2: What is the maximum acquisition rate of the PCI-1424? Question 3: How much memory does the PCI-1424 initially have? Question 4: What type of I/O connector does the PCI-1424 use? Question 5: Does the PCI-1424 support NI Vision software? |