img

188076D-04

This product features a 14-bit resolution, 100 MS/s max sample rate, and selectable impedance with a range of part numbers and software compatibility.

In Stock | Ships Today

img

    Description

    The product comes in various Part Numbers including 778758-01, 778758-02, 778758-03, 190971K-02L, and 190971J-02, offering a wide range of options for different applications. It boasts a high Resolution of 14-bit, ensuring detailed and accurate measurements in your data collection.

    With a Maximum Sample Rate of 100 MS/s, it is capable of capturing fast signals with precision. The Input Impedance is Software selectable between 50 Ω or 1 MΩ, providing flexibility in adapting to different signal sources without the need for external hardware changes.

    The Input Range spans from 200 mVpp to 20 Vpp, allowing a broad spectrum of signal amplitudes to be accurately measured. It supports Seven Trigger Modes, enabling users to precisely control the timing of their signal capture for complex experiments and tests.

    Different Onboard Memory Size Options are available, including 8 MB/ch (778758-01), 32 MB/ch (778758-02), and 256 MB/ch (778758-03), to suit various data storage needs. The Power Consumption is efficient, with a Typical usage of 29.28 W and a Maximum of 33.12 W.

    It operates within a Temperature Range of 0 to 55 °C, ensuring reliability under diverse environmental conditions. The Physical Dimensions are 8.4 x 0.8 x 5.1 in, and it has a Weight of 16 oz, making it compact and easy to integrate into various setups.

    Lastly, it is compatible with several software options including NI-SCOPE driver software, LabVIEW,

    Specification Detail
    Part Numbers 778758-01, 778758-02, 778758-03, 190971K-02L, 190971J-02
    Resolution 14-bit
    Maximum Sample Rate 100 MS/s
    Input Impedance Software selectable 50 Ω or 1 MΩ
    Input Range 200 mVpp to 20 Vpp
    Trigger Modes Seven
    Onboard Memory Size Options 8 MB/ch (778758-01), 32 MB/ch (778758-02), 256 MB/ch (778758-03)
    Power Consumption Typical: 29.28 W, Maximum: 33.12 W
    Operating Temperature Range 0 to 55 °C
    Physical Dimensions 8.4 x 0.8 x 5.1 in
    Weight 16 oz
    Software Compatibility NI-SCOPE driver software, LabVIEW, LabWindows/CVI, Measurement Studio

    Question 1: What is the maximum sample rate of the PCI-5122?
    Answer 1: 100 MS/s

    Question 2: How many trigger modes does the PCI-5122 support?
    Answer 2: Seven

    Question 3: What is the input impedance range for the PCI-5122?
    Answer 3: 50 Ω or 1 MΩ

    Question 4: What is the resolution of the PCI-5122?
    Answer 4: 14-bit

    Question 5: What software is compatible with the PCI-5122?
    Answer 5: NI-SCOPE, LabVIEW