img

188268C-03

The PXI-6651 is a low-cost slave synchronization module for PXI systems, supporting 1 MHz to 105 MHz CLKIN frequency range with a 10 MHz reference clock.

In Stock | Ships Today

img

    Description

    “`html

    The PXI-6651 is a Low Cost Slave Synchronization Module designed for precise timing and synchronization tasks. This module is identified by its part numbers 778725-01 and 188268D-03, making it a unique addition to any timing and synchronization category. It is compatible with PXI chassis, ensuring seamless integration into existing setups.

    As a slave configuration device, the PXI-6651 operates with a reference clock input of 10 MHz and supports a CLKIN frequency range from 1 MHz to 105 MHz. This wide range allows for flexible synchronization options for various applications. The module features an SMB male connector for PFI <0..1> and CLKIN, ensuring reliable and secure connections. Additionally, its input impedance is 50 ohms nominal, optimized for standard signal integrity.

    Designed to fit in a one 3U CompactPXI slot, the PXI-6651 is compact and efficient. It includes injector/ejector handles for easy installation and removal, enhancing the user experience. The module’s front panel indicators include an Access LED and an Active LED, providing immediate visual feedback on the module’s status.

    Supporting a wide range of programming environments such as LabWindows/CVI, LabVIEW, and Visual C/C++, the PXI-6651 offers versatility in development and integration into various systems. It is designed to operate within a recommended operating temperature range of 0 to 55 °C, ensuring reliability in various working conditions. Furthermore, its storage temperature range extends from -20 to providing durability and longevity.

    “`

    Specification Detail
    Part Numbers 778725-01, 188268D-03
    Category Timing and Synchronization
    Model PXI-6651
    Description Low Cost Slave Synchronization Module
    Chassis Compatibility PXI
    Configuration Slave
    Reference Clock Input 10 MHz
    CLKIN Frequency Range 1 MHz to 105 MHz
    Connector Type SMB male, PFI <0..1>, CLKIN
    Input Impedance 50 ohms nominal
    Slot Requirement One 3U CompactPXI
    Front Panel Indicators Access LED, Active LED
    Programming Environment LabWindows/CVI, LabVIEW, Visual C/C++
    Installation Feature Injector/ejector handles
    Recommended Operating Temperature 0 to 55 °C
    Storage Temperature Range -20 to

    Question 1: What is the part number of the PXI-6651?
    Answer 1: Part numbers are 778725-01 and 188268D-03.

    Question 2: What is the operating temperature range of PXI-6651?
    Answer 2: 0 to 55 °C

    Question 3: How does the PXI-6651 connect for CLKIN and PFI?
    Answer 3: Uses SMB male connector.

    Question 4: What programming environments does PXI-6651 support?
    Answer 4: LabWindows/CVI, LabVIEW, Visual C/C++.

    Question 5: What is the PXI-6651 designed for?
    Answer 5: Timing and synchronization tasks in PXI systems.