Description
The PXI-5124 is a high-performance oscilloscope module with a variety of specifications designed to meet diverse application needs. This model offers a range of part numbers including 778757-01, 778757-02, 778757-03, 778757-04, 191766A-02, 191766C-01, and 191766A-01, catering to various memory and functionality requirements.
It provides different memory options to accommodate data-intensive applications, with configurations available at 8 MB/channel (778757-01), 32 MB/channel (778757-02), 256 MB/channel (778757-03), and 512 MB/channel (778757-04), ensuring flexibility in memory allocation per channel. The sampling rate of the PXI-5124 is impressive, offering 200 MS/s with down-sampling capability, allowing for precise and detailed signal analysis.
The module features 2 input channels, facilitating the simultaneous acquisition of signals. This is complemented by a 12-bit analog resolution, ensuring that the signal integrity is maintained with high fidelity. The data transmission rate is another highlight, reaching speeds of up to 150 MHz, which enables efficient and rapid data handling.
With a maximum memory capacity of up to 512 MB per channel, the PXI-5124 stands out for its ability to handle extensive data without compromising performance. Its form factor is a compact 3U PXI module, perfectly suited for integration into PXI systems. Moreover, the interface employs a PCI bus with scatter-gather bus mastering via NI MITE ASIC, enhancing data transfer efficiency and module compatibility.
The device requires a warm-up time of 15 minutes to reach operational stability, ensuring accurate measurements. To maintain this accuracy, an external calibration interval of 2 years is recommended, which helps in sustaining the module’s performance over time. The driver software, NI-SCOPE 2.7, is specifically designed to enhance the user experience by providing intuitive control and analysis tools.
Lastly,
| Specification | Details |
|---|---|
| Model | PXI-5124 |
| Part Numbers | 778757-01, 778757-02, 778757-03, 778757-04, 191766A-02, 191766C-01, 191766A-01 |
| Memory Options | 8 MB/channel (778757-01), 32 MB/channel (778757-02), 256 MB/channel (778757-03), 512 MB/channel (778757-04) |
| Sampling Rate | 200 MS/s with down-sampling capability |
| Input Channels | 2 |
| Analog Resolution | 12-bit |
| Data Transmission | 150 MHz |
| Maximum Memory | Up to 512 MB per channel |
| Form Factor | 3U PXI module |
| Interface | PCI bus, scatter-gather bus mastering via NI MITE ASIC |
| Warm-Up Time | 15 minutes |
| External Calibration Interval | 2 years |
| Driver Software | NI-SCOPE 2.7 |
| Connectors | 3 BNC female, 2 SMB Jack,
Question 1: What is the sampling rate of the PXI-5124? Question 2: How many input channels does the PXI-5124 have? Question 3: What is the maximum memory per channel for PXI-5124? Question 4: What analog resolution does PXI-5124 offer? Question 5: How often is external calibration recommended? |