Description
The NI-9237 is a high-performance data acquisition module designed for precision sensing. This module comes with a variety of part numbers, including 780264-01, 779521-01, and 780264-02, catering to different application needs and specifications.
Equipped with 4 channels, the NI-9237 offers a sample rate of 50 kS/s per channel, ensuring high-speed data collection with minimal delay. Its ADC resolution stands at 24 bits, providing precise and accurate measurement capabilities.
For enhanced connectivity, the module supports both RJ-50 and DSUB connectors, offering flexibility in connecting various types of sensors and devices. One of the notable features of the NI-9237 is the availability of conformal coated options, specifically the part number 780264-02, which adds an extra layer of protection against harsh environments.
The module boasts an isolation rating of 60 VDC, 1000 Vrms transient, ensuring safe operation even in electrically noisy environments. Furthermore, the remote sensing capability and shunt calibration feature enhance its versatility in different application scenarios.
When it comes to software compatibility, the NI-9237 is compatible with NI-DAQmx 8.1 or later; and supports integration with various development environments, including LabVIEW, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic 6.0, Microsoft .NET, and Borland C++, making it a flexible choice for developers and engineers.
The manufacturer recommends a calibration period of either annually or every two years to ensure optimal performance and reliability of the NI-9237 module over time.
| Specification | Details |
|---|---|
| Model | NI-9237 |
| Part Numbers | 780264-01, 779521-01, 780264-02 |
| Channels | 4 |
| Sample Rate | 50 kS/s per channel |
| ADC Resolution | 24 bits |
| Connectivity Options | RJ-50, DSUB connectors |
| Conformal Coated Options | Yes (Part Number: 780264-02) |
| Isolation | 60 VDC, 1000 Vrms transient |
| Remote Sensing Capability | Yes |
| Shunt Calibration | Yes |
| Software Compatibility | NI-DAQmx 8.1 or later; LabVIEW, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic 6.0, Microsoft .NET, Borland C++ |
| Recommended Calibration Period | Annually or every two years |
Question 1: What is the sample rate per channel on the NI-9237?
Answer 1: 50 kS/s
Question 2: How many channels does the NI-9237 have?
Answer 2: 4 channels
Question 3: What ADC resolution does the NI-9237 offer?
Answer 3: 24 bits
Question 4: What types of connectors does the NI-9237 support?
Answer 4: RJ-50 and DSUB
Question 5: What is the isolation rating of the NI-9237?
Answer 5: 60 VDC, 1000 Vrms transient