img

189772C-01

The PXI-2567 is a 64-channel PXI relay driver module with overvoltage and over-current protection, supporting up to 150 operations per second.

In Stock | Ships Today

img

    Description

    The Part Number 189772C-01 refers to a PXI-2567 model, which is a 64-Channel PXI Relay Driver Module. This module is designed to manage multiple channels, precisely 64, enabling efficient control and automation within a PXI system. It comes equipped with integrated power supplies of 5 V and 12 V, complete with fuses to ensure stable operation and protect against electrical anomalies.

    Protection mechanisms are a critical aspect of the PXI-2567, offering overvoltage, over-current, and over-temperature safeguards. These protections are configured with settings not to exceed 80 V (max), 1.5 A (min), and 150°C (max), thereby ensuring the longevity and reliability of the module under various operating conditions.

    The module boasts a maximum operating speed of 150 operations per second, facilitating rapid signal processing and control tasks. Connectivity is achieved through a 78-pin D-SUB I/O connector, providing a robust and reliable physical interface for signal transmission. Moreover, the PXI-2567 supports triggering from both the front panel or PXI trigger lines 0–7, with an input trigger signal minimum pulse width of 150 ns. This feature allows for precise timing and synchronization within complex test and measurement setups.

    Regarding power requirements, the module operates on 8 W at 5 V, 0.5 W at 3.3 V, and 6 W at 12 V, with an internal drive power specification of 5 V at 1.25 A and 12 V at 0.5 A. The maximum drive voltage and current per channel are 50 VDC and 600 mA, respectively, with the module capable of handling up to 25 A in total. This ensures sufficient power for driving a wide range of devices and loads directly.

    The front panel nominal voltage is set at 3.3 V TTL, 8 mA, while the output trigger signal pulse width is programmable between 1

    Specification Detail
    Part Number 189772C-01
    Model PXI-2567
    Description 64-Channel PXI Relay Driver Module
    Channels 64
    Integrated Power Supplies 5 V and 12 V with fuses
    Protection Overvoltage, Over-current, Over-temperature
    Protection Settings 80 V (max), 1.5 A (min), 150°C (max)
    Maximum Operating Speed 150 operations per second
    Connector 78-pin D-SUB I/O connector
    Triggering Front panel or PXI trigger lines 0–7
    Input Trigger Signal Minimum Pulse Width 150 ns (with digital filtering disabled for < 150 ns)
    Power Requirement 8 W at 5 V, 0.5 W at 3.3 V, 6 W at 12 V
    Internal Drive Power 5 V at 1.25 A, 12 V at 0.5 A
    Maximum Drive Voltage 50 VDC per channel
    Maximum Drive Current 600 mA per channel, 25 A per module
    Front Panel Nominal Voltage 3.3 V TTL, 8 mA
    Output Trigger Signal Pulse Width 1 μs to 62 μs (programmable)
    Single-Channel Operate Time (at 25°C) 60 μs
    Question 1: What is the maximum operating speed of PXI-2567?
    Answer 1: 150 operations per second.

    Question 2: How many channels does PXI-2567 support?
    Answer 2: 64 channels.

    Question 3: What type of protections does PXI-2567 offer?
    Answer 3: Overvoltage, over-current, and over-temperature.

    Question 4: What is the maximum drive voltage per channel for PXI-2567?
    Answer 4: 50 VDC.

    Question 5: What is the total power requirement for PXI-2567?
    Answer 5: 14.5W (8W at 5V, 0.5W at 3.3V, 6W at 12V).