The PXI-5122 is a high-performance oscilloscope with a part number of 190100M-04L. This oscilloscope boasts a 14-Bit resolution, ensuring detailed and precise measurements. It is capable of a maximum sampling rate of 100 MS/s, making it suitable for capturing fast signals.
It offers a variety of memory options including 8 MB, 32 MB, 256 MB, and 512 MB, providing flexibility in data storage depending on the complexity of the applications. The input impedance is software selectable between 50 Ω or 1 MΩ, allowing for adaptability to different signal sources. Furthermore, the device supports an input range from 200 mVpp to 20 Vpp, accommodating a wide range of signal amplitudes.
The PXI-5122 excels in signal fidelity, featuring a spurious free dynamic range (SFDR) of 75 dBc and a signal-to-noise ratio (SNR) of 62 dB. It offers seven trigger modes, providing versatility in capturing signal events. For connectivity, it is equipped with three BNC female, 9-pin mini-circular DIN, and two SMB jack front panel connectors, ensuring compatibility with a broad range of devices.
The device operates within a temperature range of 0 to 55 °C, suitable for various environmental conditions. It supports both self-calibration and external calibration, with the latter recommended at least once every two years to maintain accuracy. The PXI-5122 is compatible with NI-SCOPE driver, LabVIEW, and LabWindows/CVI software, offering seamless integration into existing setups. A recommended warm-up time of 15 minutes is suggested for optimal performance.
| Specification | Detail |
|---|---|
| Model | PXI-5122 |
| Part Number | 190100M-04L |
| Resolution | 14-Bit |
| Maximum Sampling Rate | 100 MS/s |
| Memory Options | 8 MB, 32 MB, 256 MB, 512 MB |
| Input Impedance | 50 Ω or 1 MΩ (software selectable) |
| Input Range | 200 mVpp to 20 Vpp |
| Spurious Free Dynamic Range | 75 dBc |
| Signal-to-Noise Ratio | 62 dB |
| Trigger Modes | Seven |
| Front Panel Connectors | 3 BNC female, 9-pin mini-circular DIN, 2 SMB jack |
| Operating Temperature Range | 0 to 55 °C |
| Calibration | Self-calibration and External Calibration (recommended at least once in two years) |
| Software Compatibility | NI-SCOPE driver, LabVIEW, LabWindows/CVI |
| Recommended Warm-up Time | 15 minutes