Description
The PXI-4071 is a high-performance PXI Multimeter that carries the part number 778271-01. This device falls into the category of PXI Multimeters and is recognized as a FlexDMM, 3U PXI module. It offers a comprehensive range of measurement capabilities, including a voltage measurement range that spans from ±10 nV to 1000 V, making it suitable for a wide array of applications.
In terms of current measurement, it can measure from ±1 pA to 3 A, and for resistance measurement, the range extends from 10 µΩ to 5 GΩ. Additionally, the DC Current Range is specified as -3 A to 3 A, indicating its capability to handle both negative and positive currents effectively.
The device also boasts impressive digitizer sample rates of up to 1.8 MS/s, which allows for high-speed data acquisition. Its DC reading rates are equally noteworthy, with 7 S/s at 7 1/2 digits and 10 kS/s at 4 1/2 digits, ensuring precise and rapid measurements. For applications requiring AC measurements, the AC Coupled Auto Range Time is 250 ms, facilitating quick adjustments to varying signal levels.
Moreover, it can perform range/function changes at a rate of 10/s, demonstrating its efficiency in adapting to different measurement conditions. The trigger latency and max trigger rate are 2 µs and 1 kHz, respectively, offering reliable and responsive trigger mechanisms for synchronized measurements. However, it is important to note that the device requires a warm-up time of 1 hour to ensure accuracy in its readings.
The maintenance status of the PXI-4071 is currently available for purchase and repairs
| Specification | Details |
|---|---|
| Part Number | 778271-01 |
| Model | PXI-4071 |
| Category | PXI Multimeters |
| Type | FlexDMM, 3U PXI module |
| Voltage Measurement Range | ±10 nV to 1000 V |
| Current Measurement Range | ±1 pA to 3 A |
| Resistance Measurement Range | 10 µΩ to 5 GΩ |
| DC Current Range | -3 A to 3 A |
| Digitizer Sample Rates | Up to 1.8 MS/s |
| DC Reading Rates | 7 S/s at 7 1/2 digits, 10 kS/s at 4 1/2 digits |
| AC Coupled Auto Range Time | 250 ms |
| Range/Function Change | 10/s |
| Trigger Latency and Max Trigger Rate | 2 µs and 1 kHz |
| Warm-up Time | 1 hour |
| Maintenance Status | Available for purchase and repairs by
Question 1: What is the part number of the PXI-4071? Question 2: What voltage range can the PXI-4071 measure? Question 3: How fast can the PXI-4071 digitize signals? Question 4: What is the warm-up time for accurate readings on the PXI-4071? Question 5: Can the PXI-4071 measure both AC and DC currents? |