190353K-48L

The PXI-5142 is a 2-channel PXI Oscilloscope/Digitizer with up to 40 MHz bandwidth, 100 MS/s sample rate, and features NI TClk synchronization.

In Stock | Ships Today

img

    Description

    The PXI Oscilloscopes/Digitizers are represented by the model PXI-5142, which comes with several part numbers, including 195003E-01L, 779587-02, and 779587-01. This model features 2 channels and offers a bandwidth of up to 40 MHz. Memory size varies depending on the specific part number, with 256 MB for part number 779587-02 and 64 MB for part number 779587-01. The sample rate reaches 100 MS/s, providing high-speed data acquisition capabilities.

    The input impedance is program selectable between 50 Ω or 1 MΩ, giving users flexibility in connecting various types of signals. The input range spans from 200 mV to 20 V, accommodating a wide range of signal amplitudes. Onboard signal processing (OSP) functions include quadrature digital down-conversion (DDC), true digital down-conversion, and anti-alias filtering, enhancing the quality and integrity of measured signals.

    For complex setups requiring multiple devices or chassis, the PXI-5142 supports NI TClk synchronization, ensuring precise timing across all connected equipment. It is compatible with a variety of software tools, including the NI-SCOPE driver, LabVIEW, LabWindows/CVI, and Measurement Studio. Configuration and setup are facilitated by the Measurement & Automation Explorer (MAX) tool.

    Before achieving optimal performance, the PXI-5142 requires a warm-up time of 15 minutes. This period allows the instrument to stabilize and ensures accurate and reliable measurements.

    < Question 1: What’s the PXI-5142’s sample rate?
    Answer 1: 100 MS/s

    Question 2: How many channels does the PXI-5142 have?
    Answer 2: 2 channels

    Question 3: Does the PXI-5142 support NI TClk synchronization?
    Answer 3: Yes, it supports NI TClk synchronization.

    Question 4: What is the input impedance range of the PXI-5142?
    Answer 4: 50 Ω or 1 MΩ

    Question 5: What’s the minimum warm-up time for PXI-5142?
    Answer 5: 15 minutes

    Specification Detail
    Product Category PXI Oscilloscopes/Digitizers
    Model PXI-5142
    Part Numbers 195003E-01L, 779587-02, 779587-01
    Channels 2
    Bandwidth Up to 40 MHz
    Memory Size 256 MB (779587-02), 64 MB (779587-01)
    Sample Rate 100 MS/s
    Input Impedance Program selectable 50 Ω or 1 MΩ
    Input Range 200 mV to 20 V
    Onboard Signal Processing (OSP) Functions Quadrature digital down-conversion (DDC), True digital down-conversion, Anti-alias filtering
    Synchronization NI TClk synchronization for multi-device/chassis setups
    Software Compatibility NI-SCOPE driver, LabVIEW, LabWindows/CVI, Measurement Studio
    Configuration Tool Measurement & Automation Explorer (MAX)
    Warm-Up Time 15 minutes