The device comes with a variety of part numbers including 780320-01, 780320-02, and 780320-03, catering to different configurations or requirements. It is designed to handle 2 Simultaneously Sampled channels, providing flexibility for simultaneous data acquisition. The system boasts an impressive 1 GHz bandwidth, ensuring broad signal capture capabilities.
With a sample rate of 2 GS/s, the device offers high-speed data processing, making it suitable for capturing fast-changing signals. It operates with a resolution of 8 bits, providing adequate detail for many applications. The input impedance is set at 50 Ω, which is standard for high-frequency applications, and it supports AC, DC, GND input coupling, offering versatility in signal types that can be measured.
The DC accuracy is rated at ±1.0% of input + 1.3% of FS, ensuring reliable measurements. Additionally, the device includes a 20 MHz noise filter as a bandwidth limit filter, which is essential for reducing unwanted signal noise and improving measurement clarity. The rise/fall time is specified at 428 ps, indicating the device’s ability to accurately capture rapid signal changes.
It is equipped with 8 MB of onboard memory, capable of storing up to 32,768 records, which is beneficial for large data collection without immediate data transfer needs. The sampling range is quite flexible, ranging from 15.26 kS/s to 1 GS/s in real-time mode and 2 GS/s to 20 GS/s in random interleaved sampling mode, accommodating a wide range of sampling requirements.
For enhanced connectivity, an External Sample Clock Connectivity feature is available through a front panel SMB connector (PFI 0), allowing for precise timing and synchronization with external devices. The device also supports Self-Calibration, ensuring accurate performance over time without the need for frequent manual adjustments. Lastly, it is compatible with PCI slot installations, making it suitable for integration into
| Specification | Detail |
|---|---|
| Part Numbers | 780320-01, 780320-02, 780320-03 |
| Channels | 2 Simultaneously Sampled |
| Bandwidth | 1 GHz |
| Sample Rate | 2 GS/s |
| Resolution | 8 bits |
| Input Impedance | 50 Ω |
| Input Coupling | AC, DC, GND |
| DC Accuracy | ±1.0% of input + 1.3% of FS |
| Bandwidth Limit Filter | 20 MHz noise filter |
| Rise/Fall Time | 428 ps |
| Onboard Memory | 8 MB (up to 32,768 records) |
| Sampling Range | 15.26 kS/s to 1 GS/s real-time, 2 GS/s to 20 GS/s in random interleaved sampling mode |
| External Sample Clock Connectivity | Front panel SMB connector (PFI 0) |
| Self-Calibration | Yes |