Description
The NI PXI-4132 Precision SMU is a highly versatile instrument designed for PXI Source Measure Units category. It comes with a variety of part numbers including 190463G-01L, 780558-01, and 190463E-01L, ensuring adaptability for different configurations and requirements. This model is specifically tailored for precision measurement tasks, capable of measuring currents as low as 10 pA and voltages up to ±100 V.
The PXI-4132 excels in delivering four-quadrant output with external guarding and 4-wire sense, making it exceptionally suitable for accurate leakage measurements on integrated circuits, printed circuit boards, cables, and discrete components. It is also adept at conducting high-speed I-V measurements on components such as OLEDs and diodes, as well as more complex devices like transistors, catering to a broad spectrum of applications.
With a maximum source update rate of 4,200 updates/s and a minimal trigger into source delay of 500 ns, the PXI-4132 ensures rapid and responsive operation for dynamic testing environments. It supports a wide range of input triggers, including start, sequence, advance, source, measure, and more, as well as output triggers (events) like source complete, sequence engine done, sequence iteration complete, and measure complete, offering extensive flexibility in test setups.
This unit is designed as a 3U, one-slot, PXI module, with dimensions of 2.0 cm × 13.0 cm × 21.6 cm and a weight of 295 g, making it compact and lightweight for easy integration into PXI systems. It features an 8 position, 5.08 mm COMBICON front panel for connectivity. The maintenance phase start date for this model is December 30, 202, indicating its recent entry into the support lifecycle.
| Specification | Detail |
|---|---|
| Part Number | 190463G-01L, 780558-01, 190463E-01L |
| Category | PXI Source Measure Units |
| Model | PXI-4132 |
| Short Description | NI PXI-4132 Precision SMU |
| Measurement Capability | 10 pA, ±100 V |
| Output Type | Four-quadrant with external guarding and 4-wire sense |
| Use Case | Leakage measurements on ICs, PCBs, Cables, and discrete components |
| Applications | High-speed I-V measurements on components like OLEDs and diodes, and complex devices like transistors |
| Maximum Source Update Rate | 4,200 updates/s |
| Trigger into Source Delay | 500 ns |
| Input Triggers | Start, sequence, advance, source, measure, etc. |
| PXI Trigger Lines | 0…7 |
| Output Triggers (Events) | Source complete, sequence engine done, sequence iteration complete, measure complete |
| Form Factor | 3U, one-slot, PXI module |
| Dimensions | 2.0 cm × 13.0 cm × 21.6 cm |
| Weight | 295 g |
| Connectors | 8 position, 5.08 mm COMBICON front panel |
| Maintenance Phase Start Date | December 30, 202
Question 1: What is the part number for the NI PXI-4132? Question 2: What is the maximum voltage measurement for the PXI-4132? Question 3: How fast can the PXI-4132 update source measurements? Question 4: What is the minimum current measurement for the PXI-4132? Question 5: When did the maintenance phase for the PXI-4132 start? |




