img

190900E-02L

The cFP-TC-125 is a Compact FieldPoint with 8 differential channels, supporting B, J, E, R, K, S, N, T thermocouples and featuring built-in linearization.

In Stock | Ships Today

img

    Description

    The 190900E-02L (777318-125) is a part of the Compact FieldPoint category, specifically the model cFP-TC-125. This model is designed for precise temperature measurements and offers a 16 bit Thermocouple Input (TC, mV), capable of handling a 250V Common Mode voltage. It supports a variety of thermocouple types including B, J, E, R, K, S, N, and T, making it versatile for different temperature sensing requirements.

    The cFP-TC-125 comes equipped with 8 differential input channels, allowing for multiple measurements to be taken simultaneously. These channels can handle a Common Mode Voltage of ±250 V referenced to earth ground, and a Voltage Input Range from -20 to 80 mV. This wide range ensures accurate and reliable readings across various conditions.

    Among its notable features, the device includes built-in linearization and cold-junction compensation to improve accuracy. It also has the capability to sense open thermocouples, and it reports “Out of range” and “Open thermocouple” errors, enhancing the safety and reliability of temperature monitoring processes.

    For system integration, the cFP-TC-125 is compatible with cFP-BP-x, cFP-180x backplanes, and cFP-CB-x Connector Block. This compatibility ensures that it can be easily integrated into existing Compact FieldPoint systems, providing a seamless and efficient setup for industrial applications.

    Feature Description
    Part Number 190900E-02L (777318-125)
    Category Compact FieldPoint
    Model cFP-TC-125
    Short Description cFP-TC-125, 16 bit Thermocouple Input (TC, mV), 250V Common Mode
    Supported Thermocouple Types B, J, E, R, K, S, N, T
    Input Channels 8 differential
    Common Mode Voltage ±250 V referenced to earth ground
    Voltage Input Range -20 to 80 mV
    Features Built-in linearization, cold-junction compensation, senses open thermocouples, reports “Out of range” and “Open thermocouple” errors
    Compatible With cFP-BP-x, cFP-180x backplanes, cFP-CB-x Connector Block

    Question 1: What is the part number of cFP-TC-125?
    Answer 1: 190900E-02L (777318-125)

    Question 2: How many differential channels does cFP-TC-125 have?
    Answer 2: 8 differential input channels

    Question 3: What thermocouple types does cFP-TC-125 support?
    Answer 3: Supports B, J, E, R, K, S, N, T types

    Question 4: What is the common mode voltage of the cFP-TC-125?
    Answer 4: ±250 V referenced to earth ground

    Question 5: Does the cFP-TC-125 feature built-in linearization?
    Answer 5: Yes, it includes built-in linearization