Description
Interval
The RF Upconverter with part number 778737-01 is a high-performance device categorized under RF Upconverters. This device, model PXI-5610, is designed as a 2-slot, 3U PXI module, ensuring it fits perfectly into standard PXI slots for seamless integration into your RF applications.
The PXI-5610 boasts a wide frequency range from 250 kHz to 2.7 GHz, coupled with a 20 MHz continuous bandwidth. This wide range of frequency and bandwidth allows for flexible and versatile usage in various RF applications. The output power range of this device spans from -145 dBm to +10 dBm, accommodating a diverse range of signal power requirements. Furthermore, it offers a 130 dB flexible gain range, enabling precise control over signal amplification.
At the heart of the PXI-5610 is a high-stability OCXO timebase, with an accuracy of ±50 ppb, ensuring that your applications run with the utmost precision. The device is compatible with popular software such as LabVIEW, LabWindows/CVI, and the NI-RFSG driver software, providing a versatile programming environment. The programming interface is the NI-TUNER, which simplifies the configuration process.
The PXI-5610 supports various reference clock sources, including a high-accuracy OCXO, external sources, and the PXI backplane, offering flexibility in synchronization. It requires a 30-minute warm-up time to ensure optimal performance. The device operates efficiently within a temperature range of 0 °C to 55 °C, suitable for a wide range of working environments. Lastly, it is recommended to calibrate the unit every 1 year to maintain its high performance and accuracy.
| Specification | Detail |
|---|---|
| Part Number | 778737-01 |
| Category | RF Upconverters |
| Model | PXI-5610 |
| Form Factor | 2-slot, 3U PXI module |
| Frequency Range | 250 kHz to 2.7 GHz |
| Bandwidth | 20 MHz continuous |
| Output Power Range | -145 dBm to +10 dBm |
| Gain Range | 130 dB flexible gain |
| Timebase | High-stability OCXO |
| Timebase Accuracy | ±50 ppb |
| Compatible Software | LabVIEW, LabWindows/CVI, NI-RFSG driver software |
| Programming Interface | NI-TUNER |
| Reference Clock Sources | High-accuracy OCXO, External, PXI backplane |
| Warm-up Time | 30 minutes |
| Operating Temperature Range | 0 °C to 55 °C |
| Recommended Calibration
Question 1: What is the frequency range of the PXI-5610? Question 2: How much output power does the PXI-5610 support? Question 3: What is the accuracy of the PXI-5610’s OCXO timebase? Question 4: What is the recommended calibration interval for the PXI-5610? Question 5: What software is compatible with the PXI-5610? |