Description
The PXI Multifunction DAQ model PXI-6250, with part number 191325E-04L (779116-01), features 16 Analog Inputs and 24 Digital I/O. This device is designed to deliver comprehensive functionality for a wide range of data acquisition tasks, offering a 16-bit resolution for analog inputs and providing 24 lines of digital I/O with a 24 mA drive strength.
The maximum input voltage that the PXI-6250 can handle is 10 V, ensuring versatility in connecting various sensors and inputs. Users are recommended to calibrate the device every two years, ensuring accuracy and reliability in measurements.
With a weight of only 7.5 oz, this device is relatively lightweight, making it an excellent choice for setups where space and weight are considerations. It operates effectively within a temperature range of 0 °C to 55 °C and can be stored in temperatures ranging from -20 °C to 70 °C. The humidity range for operation is specified from 10% RH to 90% RH, under non-condensing conditions.
Regarding its durability, the PXI-6250 is designed to withstand vibrations of 0.3 grms when operating and 2.4 grms (5 to 500 Hz) in non-operating conditions. Despite being declared obsolete by National Instruments, this device is still available at Apex Waves, offering a valuable solution for those in need of reliable data acquisition hardware.
For users requiring calibration services, the device comes with NIST accredited calibration options, available through a third party. This ensures that the PXI-6250 meets stringent accuracy and performance standards, making it a trustworthy component in any data acquisition system.
| Specification | Detail |
|---|---|
| Part Number | 191325E-04L (779116-01) |
| Category | PXI Multifunction DAQ |
| Model | PXI-6250 |
| Description | 16 Analog Inputs, 24 Digital I/O |
| Analog Inputs | 16-bit resolution |
| Digital I/O | 24 lines, 24 mA drive strength |
| Maximum Input Voltage | 10 V |
| Calibration Interval | Every two years |
| Weight | 7.5 oz |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -20 °C to 70 °C |
| Humidity Range | 10% RH to 90% RH (non-condensing) |
| Vibration | Operating: 0.3 grms; Non-operating: 2.4 grms (5 to 500 Hz) |
| Obsolete Status | Declared by National Instruments, available at Apex Waves |
| Calibration Options | NIST accredited (through 3rd party
Question 1: What is the resolution of the PXI-6250’s analog inputs? Question 2: How many digital I/O lines does the PXI-6250 have? Question 3: What is the maximum input voltage for the PXI-6250? Question 4: How often should the PXI-6250 be calibrated? Question 5: Is the PXI-6250 still available despite being obsolete? |