Description
The Part Number for this device is 191332D-02 (779114-01), and it falls under the Category of PXI Multifunction DAQ. This particular model, known as the PXI-6224, is distinctively described as having 32 Analog Inputs, 48 Digital I/O. It is part of the revered M Series and interfaces via PXI.
When examining its capabilities in more detail, the device offers Analog Input Channels that can be configured as either 16 differential or 32 single ended, providing flexibility in connection types. It also includes Counters/Timers with 2 general-purpose options available, alongside 1 Frequency Generator Channel. The accuracy of measurements is backed by a Resolution of 16 bits, and the device can handle a Maximum Sample Rate of 250 kS/s.
Furthermore, the Timing Resolution is specified at 50 ns, ensuring precise timing for operations. For signal enhancement and adaptation, the device is compatible with an SCC Signal Conditioning System. It operates seamlessly with NIDAQmx Driver Software, enhancing its user-friendly nature. Before use, a Recommended Warm-Up Time of 15 minutes is suggested for optimal performance, and maintenance includes a Calibration Period of at least once a year. This device has a lightweight design, with a Weight of only 5.9 oz.
| Specification | Detail |
|---|---|
| Part Number | 191332D-02 (779114-01) |
| Category | PXI Multifunction DAQ |
| Model | PXI-6224 |
| Description | 32 Analog Inputs, 48 Digital I/O |
| Series | M Series |
| Interface | PXI |
| Analog Input Channels | 16 differential or 32 single ended |
| Counters/Timers | 2 general-purpose |
| Frequency Generator Channels | 1 |
| Resolution | 16 bits |
| Maximum Sample Rate | 250 kS/s |
| Timing Resolution | 50 ns |
| Signal Conditioning System | SCC |
| Driver Software | NIDAQmx |
| Recommended Warm-Up Time | 15 minutes |
| Calibration Period | At least once a year |
| Weight | 5.9 oz |