    The PXI-4071 is a high-precision PXI Multimeter that comes with a part number of 191485M-02L (Alternate: 778271-01). This device stands out for its exceptional performance in various measurement capabilities. It is described as a 7 1/2 Digit FlexDMM which includes a digitizer with a sample rate of up to 1.8 MS/s, and is capable of handling voltages up to 1000V and currents ranging from ±1 pA to 3 A.

    When it comes to voltage measurement, the PXI-4071 can measure within a range of ±10 nV to 1000 V. For current measurement, the range is quite extensive as well, spanning from ±1 pA to 3 A. The resistance measurement capabilities of this device are also noteworthy, with a range from 10 µΩ to 5 GΩ. This makes the PXI-4071 versatile for a wide array of applications.

    The digitizer sample rate of this multimeter can reach up to 1.8 MS/s, providing high-speed data acquisition. In terms of DC reading rates, the device can achieve 7 S/s at 7 1/2 digits, and 10 kS/s at 4 1/2 digits, ensuring accurate and fast measurements. The AC coupled auto range time is 250 ms, with a range/function change rate of 10/s, allowing for quick adjustments during operations.

    Moreover, the PXI-4071 exhibits a very low trigger latency of 2 µs, and a maximum trigger rate of 1 kHz, enhancing its performance in automated testing environments. However, it is important to note that the device requires a warm-up time of 1 hour to ensure accurate measurements. The availability of calibration for this multimeter ensures that it maintains its precision over time, making it a reliable choice for demanding applications

    Specification Detail
    Part Number 191485M-02L (Alternate: 778271-01)
    Category PXI Multimeters
    Model PXI-4071
    Description 7 1/2 Digit FlexDMM (1.8 MS/s Digitzer, 1000V, 1pA-3A)
    Voltage Measurement Range ±10 nV to 1000 V
    Current Measurement Range ±1 pA to 3 A
    Resistance Measurement Range 10 µΩ to 5 GΩ
    Digitizer Sample Rate Up to 1.8 MS/s
    DC Reading Rates 7 S/s at 7 1/2 digits, 10 kS/s at 4 1/2 digits
    AC Coupled Auto Range Time 250 ms
    Range/Function Change 10/s
    Trigger Latency and Maximum Trigger Rate 2 µs, 1 kHz
    Warm-up Time 1 hour
    Calibration Availability Question 1: What is the sample rate of the PXI-4071 digitizer?
    Answer 1: Up to 1.8 MS/s

    Question 2: What is the voltage range of the PXI-4071?
    Answer 2: ±10 nV to 1000 V

    Question 3: What is the maximum current the PXI-4071 can measure?
    Answer 3: ±1 pA to 3 A

    Question 4: How long is the warm-up time for accurate measurements?
    Answer 4: 1 hour

    Question 5: What is the part number of the PXI-4071?
    Answer 5: 191485M-02L (Alternate: 778271-01)