Description
The Part Number for this device is 191501B-03 (779121-01), indicating its unique identification within its category. Speaking of which, the device falls under the Category of PXI Multifunction DAQ, a testament to its versatility and capability in data acquisition tasks.
The specific Model of this device is PXI-6281, which provides a brief insight into its design and functionality. Its Description is succinctly put as 16 AI, 24 DIO, 2 AO, highlighting the number of Analog Inputs (AI), Digital I/O (DIO), and Analog Outputs (AO) it supports.
Delving deeper into its capabilities, the device boasts 16 channels of Analog Inputs (AI), ensuring a wide range of data can be captured simultaneously. The Resolution of these inputs is an impressive 18 Bits, allowing for high precision measurements. Additionally, it can achieve a Maximum Sample Rate of 625 kS/s, ensuring rapid data acquisition.
On the output side, it features 2 Analog Outputs (AO), providing flexibility in outputting data or control signals. The device also includes 24 Digital I/O (DIO) ports, further extending its versatility in interfacing with various digital devices.
The Driver Software that accompanies this device is NIDAQmx, known for its robustness and ease of use. It is Compatible with several Application Development Environments (ADEs) including LabVIEW and LabWindows/CVI, making it a versatile choice for developers and engineers.
Before using the device, it requires a Warm-Up Time of 15 minutes to ensure accurate performance. To maintain its precision, a Calibration Period of at least once every 2 years is recommended. This device is designed to operate within a Temperature Range of <
| Specification | Detail |
|---|---|
| Part Number | 191501B-03 (779121-01) |
| Category | PXI Multifunction DAQ |
| Model | PXI-6281 |
| Description | 16 AI, 24 DIO, 2 AO |
| Analog Inputs (AI) | 16 channels |
| Resolution | 18 Bits |
| Maximum Sample Rate | 625 kS/s |
| Analog Outputs (AO) | 2 |
| Digital I/O (DIO) | 24 |
| Driver Software | NIDAQmx |
| Compatible ADEs | LabVIEW, LabWindows/CVI |
| Warm-Up Time | 15 minutes |
| Calibration Period | At least once every 2 years |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -20 °C to 70 °C |
| Humidity Range | 10% RH to 90% RH (non
Question 1: What is the part number of the PXI-6281? Question 2: How many analog inputs does the PXI-6281 have? Question 3: What is the maximum sample rate of the PXI-6281? Question 4: What resolution do the analog inputs of the PXI-6281 support? Question 5: What driver software is compatible with the PXI-6281? |