Description
The Part Number for this device is 191501D-02 (779122-01), categorized under PXI Multifunction DAQ with the model number PXI-6284. This device is designed to provide comprehensive data acquisition functionalities with 32 Analog Inputs and 48 Digital I/O, making it suitable for a wide range of applications.
It boasts an impressive 18-bit resolution on the analog inputs, ensuring high precision in measurements. The device supports prescaling at 8X and 2X, enhancing its versatility in handling various signal levels. Additionally, it includes a feature for Duplicate Count Prevention, ensuring data integrity by avoiding multiple counts of the same event.
The driver software provided is NI-DAQmx, which is compatible with several programming environments including LabVIEW, LabWindows/CVI, and Measurement Studio. This compatibility ensures that users can easily integrate the device into their existing systems without the need for extensive modifications.
An important feature of this device is its Digital Isolation, which enhances the safety and reliability of the system by isolating the digital inputs and outputs from the rest of the system. Connectivity is facilitated through 2 68-pin VHDCI connectors, providing robust and reliable connections.
Before achieving optimal performance, the device requires a warm-up time of 15 minutes. To maintain its accuracy and reliability, a calibration period of at least once every 2 years is recommended. The device is lightweight, weighing only 8.1 oz, and operates within a temperature range of 0 °C to 55 °C, accommodating various working environments.
| Specification | Detail |
|---|---|
| Part Number | 191501D-02 (779122-01) |
| Category | PXI Multifunction DAQ |
| Model | PXI-6284 |
| Description | 32 Analog Inputs, 48 Digital I/O |
| Analog Input Channels | 32 |
| Resolution | 18-bit |
| Prescaling | 8X and 2X |
| Duplicate Count Prevention | Yes |
| Driver Software | NI-DAQmx |
| Compatible Software | LabVIEW, LabWindows/CVI, Measurement Studio |
| Digital Isolation | Yes |
| I/O Connectors | 2 68-pin VHDCI |
| Warm-up Time | 15 minutes |
| Calibration Period | At least once every 2 years |
| Weight | 8.1 oz |
| Operating Temperature Range | 0 °C to 55 °C |
| Question 1: What is the resolution of the PXI-6284’s analog inputs? Answer 1: 18-bit Question 2: How many analog and digital I/O does the PXI-6284 have? Question 3: What software is compatible with the PXI-6284? Question 4: What type of connectors does the PXI-6284 use? Question 5: How often is calibration recommended for the PXI-6284? |