191766F-03L

This 3U PXI module features 2 input channels, up to 512 MB memory/channel, 200 MS/s rate, and requires external calibration every 2 years.

In Stock | Ships Today

img

    Description

    This product comes with a variety of Part Numbers, including 778757-01, 778757-02, 778757-03, 778757-04, 191766A-02, 191766C-01, and 191766A-01, to meet diverse customer needs. Each part number correlates with different Memory Options, offering flexibility in memory capacity per channel: 8 MB for 778757-01, 32 MB for 778757-02, 256 MB for 778757-03, and a substantial 512 MB for 778757-04.

    The device is equipped with 2 input channels, providing a means to receive signals from multiple sources simultaneously. It boasts an Analog Resolution of 12-bit, ensuring detailed and accurate signal representation. With a Maximum Sampling Rate of 200 MS/s simultaneous, it is capable of capturing rapid signal changes, and its Bandwidth of 150 MHz allows it to accurately process high-frequency signals.

    The Maximum Memory per Channel is a significant 512 MB, facilitating extensive data capture and storage. Designed as a 3U PXI module, it integrates seamlessly into PXI systems, offering a compact and efficient solution for data acquisition and signal processing. The Driver Software, NI-SCOPE 2.7, supports a broad range of development environments, enhancing its versatility.

    Connection options are ample, with 3 BNC female, 2 SMB Jack, and 1 9-pin mini-circular DIN connectors, accommodating a variety of signal sources and external devices. It requires an External calibration every 2 years, ensuring long-term accuracy and reliability. The recommended Warm-Up Time is 15 minutes, allowing for precise measurements shortly after power-up.

    As of December 30, 2022, the product entered the Maintenance phase, indicating continued support and service availability. This includes a Calibration Service, ensuring that the device remains within its specified operational parameters over time.

    Question 1: How many input channels does the PXI-5124 have?
    Answer 1: 2 input channels

    Question 2: What is the maximum memory per channel for PXI-5124?
    Answer 2: 512 MB

    Question 3: What is the maximum sampling rate of the PXI-5124?
    Answer 3: 200 MS/s

    Question 4: How often does the PXI-5124 require external calibration?
    Answer 4: Every 2 years

    Question 5: What software driver supports the PXI-5124?
    Answer 5: NI-SCOPE 2.7

    Specification Detail
    Part Numbers 778757-01, 778757-02, 778757-03, 778757-04, 191766A-02, 191766C-01, 191766A-01
    Memory Options 8 MB/channel (778757-01), 32 MB/channel (778757-02), 256 MB/channel (778757-03), 512 MB/channel (778757-04)
    Channels 2 input channels
    Analog Resolution 12-bit
    Maximum Sampling Rate 200 MS/s simultaneous
    Bandwidth 150 MHz
    Maximum Memory per Channel 512 MB
    Form Factor 3U PXI module
    Driver Software NI-SCOPE 2.7
    Connectors 3 BNC female, 2 SMB Jack, 1 9-pin mini-circular DIN
    Calibration Interval External calibration every 2 years
    Warm-Up Time 15 minutes
    Support Status Maintenance phase as of December 30, 2022